DSC Power432 PC585 Manual de instalación Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
44
Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using
the standard (non-automatic) Contact ID reporting format.
Table 3: SIA Format Automatic Zone Alarm/
Restoral
Section # Reporting Code Code Sent When...
Dialer
Direction*
Contact
ID Codes
SIA Auto Rep
Codes**
[350] TLM Restore Telephone line trouble restore MA/R (3) 51 LR-00
[349-350] Gen System Supervisory
Trouble/Rest.
control panel loses/restores communications with mod-
ule(s) connected to the Keybus
MA/R (3) 33 ET-00/ER-00
[351] Line 1 or 2 FTC Restoral control panel has restored communications to central
station on line 1 or 2 (after FTC)
MA/R (3) 54 YK-00
[351] Event Buffer is 75% Full event buffer is almost full since last upload MA/R (6) 23 JL-00
[351] DLS Lead In downloading session start MA/R (4) 11 RB-00
[351] DLS Lead Out downloading session complete MA/R (4) 12 RS-00
[351] Zone Fault/Rest. one or more zones have faults/restored MA/R (3) 72 UT-00/UJ-00
[351] Delinquency programmed amount of time (days or hours) for delin-
quency has expired without zone activity or without sys-
tem being armed
MA/R (4) 54*** CD-00
[352] Periodic Test periodic system test transmission T (6) A2 RP-00
[352] System Test [*][6] bell/communications test T (6) A1 RX-00
[352] LINKS Test LINKS test transmission T (6) A3 TX-00
[353] Wireless Device Low Battery
Trouble/Rest.
wireless zones (WLS904, WLS905, WLS907); panic
pendants (WLS908); handheld keypads (WLS910);
wireless keys (WLS909) have low battery/all low batter-
ies restored
MA/R (3) 84 XT-00/XR-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency.
Make sure your central station is aware of the application of this reporting code.
Medical Alarms (1)34 Entry / Exit
(1)AA Medical (1)35 Day / Night
(1)A1 Pendant Transmitter (1)36 Outdoor
(1)A2 Fail to Report In (1)37 Tamper
Fire Alarms (1)38 Near Alarm
(1)1A Fire Alarm General Alarms
(1)11 Smoke (1)4A General Alarm
(1)12 Combustion (1)43 Exp. module failure
(1)13 Water Flow (1)44 Sensor tamper
(1)14 Heat (1)45 Module Tamper
(1)15 Pull Station
(1)4A Cross Zone Police Code
(1)16 Duct 24-hr Non-Burglary
(1)17 Flame (1)5A 24-hr non-Burg
(1)18 Near Alarm (1)51 Gas detected
Panic Alarms (1)52 Refrigeration
(1)2A Panic (1)53 Loss of Heat
(1)21 Duress (1)54 Water Leakage
(1)22 Silent (1)55 Foil Break
(1)23 Audible (1)56 Day Trouble
Burglar Alarms (1)57 Low bottled Gas level
(1)3A Burglary (1)58 High Temp
(1)31 Perimeter (1)59 Low Temp
(1)32 Interior (1)61 Loss of Air Flow
(1)33 24-hr
Zone Definition
SIA Auto Rep
Codes*
Contact ID Auto
Rep Codes*
Zone Alm/Rest. Zone Alm/Rest.
Delay 1 BA-ZZ/BH-ZZ (1) 3A
Delay 2 BA-ZZ/BH-ZZ (1) 3A
Instant BA-ZZ/BH-ZZ (1) 3A
Interior BA-ZZ/BH-ZZ (1) 3A
Interior Stay/Away BA-ZZ/BH-ZZ (1) 3A
Delay Stay/Away BA-ZZ/BH-ZZ (1) 3A
Delayed 24-hr Fire FA-ZZ/FH-ZZ (1) 1A
Standard 24-hr Fire FA-ZZ/FH-ZZ (1) 1A
24-hr Supervisory US-ZZ/UR-ZZ (3) 8A
24-hr Supervisory Buzzer UA-ZZ/UH-ZZ (1) 3A
24-hr Burg BA-ZZ/BH-ZZ (1) 3A
24-hr Holdup HA-ZZ/HH-ZZ (1) 22
24-hr Gas GA-ZZ/GH-ZZ (1) 5A
24-hr Heat KA-ZZ/KH-ZZ (1) 5A
24-hr Medical MA-ZZ/MH-ZZ (1) AA
24-hr Panic PA-ZZ/PH-ZZ (1) 2A
24-hr Emergency (non-medical) QA-ZZ/QH-ZZ (1) 1A
24-hr Sprinkler SA-ZZ/SH-ZZ (1) 13
24-hr Waterflow WA-ZZ/WH-ZZ (1) 5A
24-hr Freeze ZA-ZZ/ZH-ZZ (1) 5A
24-hr Latching BA-ZZ/BH-ZZ (1) 3A
* ZZ = zones 01-32