Power864
SECURITY SYSTEM
®
TM
WARNING
This manual contains information on limitations regarding product use
and function and information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
User’s
Guide
Now classified in accordance with ANSI/SIA CP-01-2000 (SIA-FAR)
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - Power864

Power864SECURITY SYSTEM®TMWARNING This manual contains information on limitations regarding product useand function and information on the limitations

Pagina 2 - Quick Reference Guide

6Section 2: Arming and Disarming Your SystemThis section describes how to perform the basic functions of your system: arming and dis-arming. Read this

Pagina 3 - Table of Contents

Arming and Disarming Your System: Arming Your System7Arming Your System There are two basic methods for arming your security system. • Away Arming: Us

Pagina 4 - System Information 25

8Bell/Siren Sounds After Away ArmingAudible Exit FaultIn an attempt to reduce false alarms, the Audible Exit Fault is designed to notify you of an imp

Pagina 5 - Keypad Buttons & Lights

Arming and Disarming Your System: Quick Arm9Re-activate bypassed zonesTo fully arm the system when it has been armed in Stay mode:1. Press at any k

Pagina 6

10Automatic ArmingYour installer may have set up your system to arm at a pre-programmed time. If automatic arming has been programmed, when the system

Pagina 7 - About This Guide

Arming and Disarming Your System: Quick Exit11Quick ExitYour installer will tell you if the Quick Exit feature has been enabled on your system. The Qu

Pagina 8 - Section 1: Introduction

12Section 3: Dealing With Alarms and EmergenciesIf you return to the premises and the bell or siren is on - DO NOT ENTER. Contact local authorities f

Pagina 9 - Introduction: Fire Detection

13Intrusion (Burglary) AlarmsA steady bell or siren indicates an intrusion alarm. To silence the alarm:1. Enter your [access code]. 2. If the alarm wa

Pagina 10 - Getting Ready

14Calling for Help All keypads have three pairs of emergency keys. Using these keys you can send an immedi-ate Fire, Auxiliary or Panic message to you

Pagina 11 - Away Arming

15Section 4: Using Advanced FunctionsThis section describes how to perform more specialized functions: bypassing zones, turning the door chime on or o

Pagina 12 - Stay Arming

Quick Reference GuideThe following chart lists the basic functions of your system alphabetically, and the keys to press foreach function. Refer to the

Pagina 13

16Recalling Bypassed ZonesTo recall the last set of bypassed zones:1. Press , then your [access code] (if necessary).2. Press . 3. To exit bypassing

Pagina 14 - Automatic

Using Advanced Functions: Identifying Trouble Conditions17Identifying Trouble ConditionsYour system continuously checks for a number of possible troub

Pagina 15

18Zone Light Type Of Trouble7 Low zone battery. This trouble is generated when a wireless device has a low battery. This trouble only applies if you h

Pagina 16 - Fire Alarms

Using Advanced Functions: Allowing Computer Access to Your System19LCD5500Z/LCD5520Z keypads will display the following message when each zone (detect

Pagina 17

20Section 5: Customizing Your SystemThis section describes how to customize your system to your needs. Refer to this section for detailed instructions

Pagina 18

21Setting the Time and DateYou should make sure that your system has the correct time and date. This is important for the auto-arm feature to function

Pagina 19 - Bypassing

22Section 6: Fire SafetyRead this section carefully for important information about fire safety.Household Fire Safety AuditMost fires occur in the hom

Pagina 20

23Section 7: GlossaryAccess codeA 4- or 6-digit code that allows access to arming, disarming and other system functions.AlarmWhen a zone is violated (

Pagina 21 - Conditions

24Exit delayA timer programmed by your installer. It starts when you arm your system, to allow you a period of time in which to leave the premises. At

Pagina 22

25Section 8: System InformationFill out the following information for future reference and store this guide in a safe place.For ServiceCentral Station

Pagina 23

Table of ContentsKeypad Buttons & Lights 1 Displays (LCD Keypads): ...

Pagina 24 - Access Codes

26Zone InformationThere are ________ active zones on the system.Zone Protected Area Zone Type Zone Protected Area Zone Type01 3302 3403 3504 3605 3706

Pagina 25

27IndexAAccess codesadding 20changing 20defined 23erasing 20Master code 24programming 20Alarmdefined 23false 12fire 12intrusion 13memory 13viewing 13A

Pagina 26 - Section 6: Fire Safety

Limited WarrantyDigital Security Controls Ltd. warrants the original purchaser that for a period oftwelve months from the date of purchase, the produc

Pagina 27 - Section 7: Glossary

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact withsystem users, it is your

Pagina 28

FCC COMPLIANCE STATEMENTFCC COMPLIANCE STATEMENTFCC COMPLIANCE STATEMENTFCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approv

Pagina 30 - Zone Information

29005909R004©2003 Digital Security Controls Ltd.Toronto, CanadaPrinted in Canada 29005909 Rev 004NOTICE: The Industry Canada label identifies certifi

Pagina 31

Customizing Your System 20Programming Access Codes ...2

Pagina 32 - Limited Warranty

1Keypad Buttons & LightsPC5508Z PC5516ZLCD5500Z/LCD5520ZLCD5501Z KeypadPC5532Z (LED) KeypadYour installer may have installedone of these LED keypa

Pagina 33 - WARNING

2➊ Displays (LCD Keypads):Fixed Message Display (LCD5501Z Keypad)Shows the status of your security system using an LCD showing fixed words/icons and n

Pagina 34 - FCC COMPLIANCE STATEMENT

3About This GuideThis Power864 User’s Guide is for anybody using a Power864 Security System. Read this guide thoroughly to learn how to use your secur

Pagina 35

4Section 1: IntroductionYour security system can provide up to three kinds of monitoring: intrusion, fire, and emer-gency. We have designed your DSC P

Pagina 36 - Toronto, Canada

Introduction: Fire Detection5Fire DetectionThis equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warn