SYSTEM FEATURES, CONTINUED
FLEXIBLE COMMUNICATIONS
• Door chime...
- monitor a zone by having the keypad beep when the zone is
open and again when it is closed
128-event alarm history buffer...
- all events are automatically stored in a memory buffer with
time and date stamp
- events can be uploaded, viewed, and printed on a PC using
DLS-3 software
Local PC-Link & remote upload/download capability...
- program the system using DLS-3 software and direct PC connection
to the control panel or from a remote PC over the telephone line
- view status and trouble conditions, and system’s 128-event buffer
- remote access can be controlled by owner to prevent unauthorized
access to the system
• EEPROM memory...
- system will not lose programming or system status on complete AC
and battery failure (will lose recorded zone labels)
Power requirements...
- 9 VAC, 20 VA plug-in transformer (supplied)
- 6 volt, 3.5 Ah rechargeable sealed lead acid battery (supplied)
System is continuously monitored for the following
trouble conditions:
- System low battery
- Fire trouble
- AC power failure
- Telephone line trouble
- Device low battery
- Loss of internal clock
- Zone faults and tampers
- Failure to communicate
- RF jamming
Digital telephone communicator fully programmable for...
- individual reporting of all alarms, supervisories, and restorals
- open/close, partial close reporting by access code
- supports all major formats including SIA, Contact ID, and
20 bps formats
- automatic SIA & Contact ID reporting codes
- 3 telephone numbers
- 2 account codes
- DTMF and pulse dialing
- DPDT line seizure
- split reporting of selected transmissions to each telephone number
- event-initiated personal paging
- alternate wireless communications using Skyroute or
LINKS transmitters
FULLY SUPERVISED
FALSE ALARM PREVENTION
LCD-DRIVEN ‘FLASH PROGRAMMING’
POWER-DRIVEN
Audible exit delay
Audible exit fault
• ‘Quick Exit’
‘Urgency’ on entry delay
• Swinger shutdown
Recent closing transmission
• Communication delay
Rotating keypress buffer
Arm/disarm bell squawk
Provides instructions to guide installer through
the programming of...
- device enrollment on a specific zone
- central station telephone number
- system account code
- placement tests for each wireless detector
Automatically determines the type of detector (e.g.,
contact -vs- PIR) and sets default zone definitions to
suit standard installations
- these may be programmed to accommodate custom
installation requirements
‘Flash Programming’ placement test ensures reliable
communications between the main control unit and
the detectors
Offers the functionality and feature set of the proven
PowerSeries
security systems
DESK-MOUNT KIT
SYSTEM PACK
NT9005DMK
Converts any Envoy LCD wall-
mount system into a convenient
desktop model
Reduces installation time
Comes with two 6ft (1.8m)
phone cables
ENVOYLCD1... System Pack
NT9005-433... main control unit
One 9V, 20VA plug-in transformer
One 6V, 3.5Ah rechargeable sealed lead acid battery
2 WLS925L-433... mini door/window contacts
1 WLS904PL-433... PIR motion detector with pet immunity
LCD Spec Sheet 10/4/01 7:48 Page 3