SYSTEM FEATURES, CONTINUED
FLEXIBLE COMMUNICATIONS
• Door chime...
- monitor a zone by having the keypad beep when the zone is
open and again when it is closed
• 128-event alarm history buffer...
- all events are automatically stored in a memory buffer with
time and date stamp
- events can be uploaded, viewed, and printed on a PC using
DLS-3 software
• Local PC-Link & remote upload/download capability...
- program the system using DLS-3 software and direct PC connection
to the control panel or from a remote PC over the telephone line
- view status and trouble conditions, and system’s 128-event buffer
- remote access can be controlled by owner to prevent unauthorized
access to the system
• EEPROM memory...
- system will not lose programming or system status on complete AC
and battery failure (will lose recorded zone labels)
• Power requirements...
- 9 VAC, 20 VA plug-in transformer (supplied)
- 6 volt, 3.5 Ah rechargeable sealed lead acid battery (supplied)
• System is continuously monitored for the following
trouble conditions:
- System low battery
- Fire trouble
- AC power failure
- Telephone line trouble
- Device low battery
- Loss of internal clock
- Zone faults and tampers
- Failure to communicate
- RF jamming
• Digital telephone communicator fully programmable for...
- individual reporting of all alarms, supervisories, and restorals
- open/close, partial close reporting by access code
- supports all major formats including SIA, Contact ID, and
20 bps formats
- automatic SIA & Contact ID reporting codes
- 3 telephone numbers
- 2 account codes
- DTMF and pulse dialing
- DPDT line seizure
- split reporting of selected transmissions to each telephone number
- event-initiated personal paging
- alternate wireless communications using Skyroute or
LINKS transmitters
FULLY SUPERVISED
FALSE ALARM PREVENTION
LCD-DRIVEN ‘FLASH PROGRAMMING’
POWER-DRIVEN
• Audible exit delay
• Audible exit fault
• ‘Quick Exit’
• ‘Urgency’ on entry delay
• Swinger shutdown
• Recent closing transmission
• Communication delay
• Rotating keypress buffer
• Arm/disarm bell squawk
• Provides instructions to guide installer through
the programming of...
- device enrollment on a specific zone
- central station telephone number
- system account code
- placement tests for each wireless detector
• Automatically determines the type of detector (e.g.,
contact -vs- PIR) and sets default zone definitions to
suit standard installations
- these may be programmed to accommodate custom
installation requirements
• ‘Flash Programming’ placement test ensures reliable
communications between the main control unit and
the detectors
• Offers the functionality and feature set of the proven
PowerSeries
™
security systems
DESK-MOUNT KIT
SYSTEM PACK
NT9005DMK
• Converts any Envoy LCD wall-
mount system into a convenient
desktop model
• Reduces installation time
• Comes with two 6ft (1.8m)
phone cables
ENVOYLCD1... System Pack
• NT9005-433... main control unit
• One 9V, 20VA plug-in transformer
• One 6V, 3.5Ah rechargeable sealed lead acid battery
• 2 WLS925L-433... mini door/window contacts
• 1 WLS904PL-433... PIR motion detector with pet immunity