DSC PowerSeries Guía de instalación

Busca en linea o descarga Guía de instalación para Los Sistemas De Control De Acceso De Seguridad DSC PowerSeries. DSC PowerSeries Installation guide [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PowerSeries
PC1616/PC1808/PC1832/PC1864 version 4.2 S.Africa
Installation Guide
WARNING: This manual contains information on limitations regarding product use and function and
information on the limitations as to liability the manufacturer. The entire manual should be carefully read.
Vista de pagina 0
1 2 3 4 5 6 ... 63 64

Indice de contenidos

Pagina 1 - PowerSeries

PowerSeries PC1616/PC1808/PC1832/PC1864 version 4.2 S.AfricaInstallation GuideWARNING: This manual contains information on limitations regarding produ

Pagina 2 - Table of Contents

PowerSeries - PC1616/PC1808/PC1832/PC18648Section 3: ProgrammingThis section provides the information necessary to program all required features for a

Pagina 3 - Installation

Section 3: Programming9The Armed and Ready lights indicate programming status:Armed Light ON Panel waiting for 3-digit section numberIf in module prog

Pagina 4 - Burglary Zone Wiring Chart

PowerSeries - PC1616/PC1808/PC1832/PC186410Section 4 – Programming DescriptionsThe following is a brief description of the features and options availa

Pagina 5 - PC1616/1808/1832/1864

Section 4 – Programming Descriptions11Section [005] System TimesAfter entering Section [005], enter the 2-digit subsection number for the desired part

Pagina 6 - DC - 14VDC

PowerSeries - PC1616/PC1808/PC1832/PC186412Section [012] Keypad LockoutThe system can be programmed to ‘lockout’ keypads if a series of incorrect user

Pagina 7 - Section 2: User Commands

Section 4 – Programming Descriptions13Section [014] Second System Option CodeSection [015] Third System Option Code[5] ON: auto-arming schedules (Prog

Pagina 8 - Master Code all functions

PowerSeries - PC1616/PC1808/PC1832/PC186414Section [016] Fourth System Option CodeSection [017] Fifth System Option CodeSection [018] Sixth System Opt

Pagina 9

Section 4 – Programming Descriptions15Section [019] Seventh System Option CodeSection [020] Keypad Zone AssignmentEnter the two-digit zone number to b

Pagina 10 - Section 3: Programming

PowerSeries - PC1616/PC1808/PC1832/PC186416Section [023] Tenth System Option CodeSection [030] Fast Loop ResponseThis section is used to determine the

Pagina 11

Section 4 – Programming Descriptions17Keypad zones and zone expanders will always follow Section [013].When Zone Types (Section [001] to [004]) are pr

Pagina 12

Table of ContentsSection Description Page11.11.21.31.41.51.61.71.81.91.10Installation & Wiring...

Pagina 13 - Section [007] Master Code

PowerSeries - PC1616/PC1808/PC1832/PC186418Section [170] PGM Output TimerProgram the time, in seconds, PGM outputs programmed to follow the PGM Output

Pagina 14 - Section [012] Keypad Lockout

Section 4 – Programming Descriptions19different format, this account number will be used for all events that are not partition specific (for example,

Pagina 15 - ][5] command

PowerSeries - PC1616/PC1808/PC1832/PC186420Section [379] Periodic DLS Time of Day Programs the time the system will auto-call DLS. Program 4 digits –

Pagina 16

Section 4 – Programming Descriptions21Section [383] Fourth Communicator Option CodeSection [389] T-Link Fault Check TimerProgram the period of time (i

Pagina 17 - ][3] menu access

PowerSeries - PC1616/PC1808/PC1832/PC186422Section [404] Panel Identification CodeProgram the 6-digit Panel Identification Code. This code is used by

Pagina 18

Section 4 – Programming Descriptions23PGM Output Option [31]PGM Output Option [32]PGM Output Option [29] and [35]-[41]Section [551] to [564] PGM Parti

Pagina 19

PowerSeries - PC1616/PC1808/PC1832/PC186424Section [601] to [608] Additional Reporting Codes Program the reporting code for all events to be transmitt

Pagina 20 - ] key press

Section 4 – Programming Descriptions25Section [703] Delay Between Dialing AttemptsProgram the time the panel will wait between dialing attempts to tra

Pagina 21

PowerSeries - PC1616/PC1808/PC1832/PC186426Section [904]: Wireless Placement TestEnter Section [904] followed by the 2-digit number of the wireless zo

Pagina 22

Section 5: Programming Work Sheets27Section 5: Programming Work Sheets5.1 Index to Programming Work SheetsProgramming Option Page[000] Keypad Enrollme

Pagina 23

Section 1: Installation & Wiring1Section 1: Installation & WiringThis Installation Guide provides the basic installation, wiring and programmi

Pagina 24

PowerSeries - PC1616/PC1808/PC1832/PC1864285.2 Programming Worksheets Shaded programming sections indicate minimum programming requirements\Keypad Par

Pagina 25

5.2 Programming Worksheets29[005] System Times Exit Time Restart shall be disabled when the panel is used in combination with T-Link TL250/TL300. Sec

Pagina 26

PowerSeries - PC1616/PC1808/PC1832/PC186430Programmable Output Options01 Residential Burglary and Fire Bell Output 18 Stay Armed Status 36 Zone Foll

Pagina 27

5.2 Programming Worksheets31[013] First System Options[014] Second System Options[015] Third System Options[016] Fourth System OptionsOpt Def ON OFF1R

Pagina 28

PowerSeries - PC1616/PC1808/PC1832/PC186432[017] Fifth System Options[018] Sixth System Options[019] Seventh System Options Keypad Zone Assignments[02

Pagina 29 - Programming Option Page

5.2 Programming Worksheets33[021] Eighth System Options[022] Ninth System Options [023] Tenth System Options[030] Zone Loop Response (Zones 1-8)Opt De

Pagina 30 - 5.2 Programming Worksheets

PowerSeries - PC1616/PC1808/PC1832/PC186434[101]-[164] Zone Attributes Zone Attribute Defaults (Y = Option ON; N = Option OFF): Attribute: 123456 789O

Pagina 31 - [005] System Times

5.2 Programming Worksheets35Section Zone # Zone Audible/ Steady/ Chime Bypass Force* Swing Tx. Delay Wireless Cross ZnType** Silent Pulsed No No No N

Pagina 32 - Other System Options

PowerSeries - PC1616/PC1808/PC1832/PC186436Section Zone # Zone Audible/ Steady/ Chime Bypass Force* Swing Tx. Delay Wireless Cross Zn Type** Silent Pu

Pagina 33

5.2 Programming Worksheets37[167] T-LINK Interface Communications Wait for Acknowledge Default 020 I_______I_______I_______I Valid entries are 001-255

Pagina 34

PowerSeries - PC1616/PC1808/PC1832/PC186421.1 Keybus WiringThe 4-wire KEYBUS (red, black, yellow and green) is the communication connection between th

Pagina 35 - 4][1], [4][2], [4][3]

PowerSeries - PC1616/PC1808/PC1832/PC186438No Activity Arming Timers - Default is [000] for all partitionsSection Partition[191] 1 I_______I_______I_

Pagina 36 - [101]-[164] Zone Attributes

5.2 Programming Worksheets39Communications[304] Call Waiting Cancel String (6 Digits) - This feature is activated in Section 382 Opt 4I_______I_______

Pagina 37

PowerSeries - PC1616/PC1808/PC1832/PC186440[324]-[327] Alarm Restoral Reporting Codes, Zones 01-64 Section[324] Zone 01 Zone 02 Zone 03 Zone 04 Zone

Pagina 38 - System Timers

5.2 Programming Worksheets41[334]-[337] Tamper Restoral Reporting Codes, Zones 01-64 Section[334] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Z

Pagina 39

PowerSeries - PC1616/PC1808/PC1832/PC186442 [344] Miscellaneous Opening (Disarming) Reporting CodesI_______I_______IFor Future UseI_______I_______IFor

Pagina 40

5.2 Programming Worksheets43Call Direction Options[351]-[358] Alarm/Restore Communicator Call Directions [359]-[366] Tamper/Restore Communicator Call

Pagina 41

PowerSeries - PC1616/PC1808/PC1832/PC186444[375] System Maintenance Communicator Call Directions [376] System Test Transmissions Communicator Call Dir

Pagina 42

5.2 Programming Worksheets45[381] Second Communicator Options[382] Third Communicator Options* A Call Waiting Cancel on a non-Call Waiting line will p

Pagina 43

PowerSeries - PC1616/PC1808/PC1832/PC186446[402] DLS Downloading Telephone Number (32 Digits)|____D___|_______|_______|_______|_______|_______|_______

Pagina 44

5.2 Programming Worksheets47Section PGM Output 1 2 3 4 5

Pagina 45

3PC1616/1808/1832/1864 Wiring DiagramPC Boar d Cabinet Stand Of f Pr imar y:120V A C/60Hz. Secondar y: 16.5VDC 40V A DSCPTD 1640U Class II Tr ansf o

Pagina 46

PowerSeries - PC1616/PC1808/PC1832/PC186448PGM Output Partition AssignmentSection PGM Partition: 1 2 3 4 5 6 7 8#Main Board[551] 1 I________I I______

Pagina 47

5.2 Programming Worksheets49[605]-[608] Opening (Disarming) Reporting Codes, Access Codes 33-95Section [605] Code 33 Code 34 Code 35 Code 36 Code 37

Pagina 48 - Attribute: 12 3 4 5 678

PowerSeries - PC1616/PC1808/PC1832/PC186450INTERNATIONAL PROGRAMMING[700] Automatic Clock Adjust Default = 60 |________|_________| Valid Entr

Pagina 49

INTERNATIONAL PROGRAMMING51Module Programming[801] PC5400 Printer Module Programming Refer to the PC5400 Installation Manual for installation and prog

Pagina 50 - Extended Reporting Codes

PowerSeries - PC1616/PC1808/PC1832/PC186452For the RecordCustomer: ___________________________________________________________________________________

Pagina 51

INTERNATIONAL PROGRAMMING53Zone Programming SummaryZone programming can be found in sections [001] - [004], [101] - [164], [020], [202]-[265]. Use thi

Pagina 52

PowerSeries - PC1616/PC1808/PC1832/PC1864Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA format reporting codes.

Pagina 53

Appendix A: Reporting Codes[345]-[346] Auxiliary Power Trouble/Rest.Aux voltage supply trouble/restoral MA/R (3) 12 YP-00/YQ-00[345] TLM Failure Telep

Pagina 54 - For the Record

PowerSeries - PC1616/PC1808/PC1832/PC1864Appendix B: Troubleshooting GuideTesting:• Power up system• Program options as required (See Programming Sec

Pagina 55 - Zone Programming Summary

Appendix B: Troubleshooting GuideTrouble Cause TroubleshootingTrouble [1] Service Required Press [1] to determine specific trou

Pagina 56 - Appendix A: Reporting Codes

PowerSeries - PC1616/PC1808/PC1832/PC186441.5 AUX Power WiringThe control panel can provide a maximum of 700mA of current for modules, powered detecto

Pagina 57 - Appendix A: Reporting Codes

PowerSeries - PC1616/PC1808/PC1832/PC1864Trouble Cause TroubleshootingTrouble [2] AC FailureNo AC at panel AC input terminalsVerify voltage measured a

Pagina 58 - Trouble Summary:

Appendix B: Troubleshooting GuideTrouble Cause TroubleshootingTrouble [5] Zone Fault (Cont.)One or more wireless devices have not checked in within th

Pagina 59 - Trouble Cause Troubleshooting

PowerSeries - PC1616/PC1808/PC1832/PC1864Appendix C: Template ProgrammingTemplate programming allows quick programming of the minimum functions requir

Pagina 60

Appendix C: Template ProgrammingSelected TroublesOpenings & ClosingsZone Restorals DLS/Installer Lead IN/OUTDigit 5 selects DLS connection options

Pagina 61

Note to InstallersThis warning contains vital information. As the only individual in contact with system users, it is yourresponsibility to bring each

Pagina 62 - Common Group

Section 2: User Commands5Section 2: User CommandsAny system keypad can be used to program or perform any keypad command. LED keypads use status and zo

Pagina 63 - DLS/Installer Lead IN/OUT

PowerSeries - PC1616/PC1808/PC1832/PC18646[][2] Trouble DisplayRefer to Appendix D – Trouble Conditions, for troubleshooting assistance and a detaile

Pagina 64 - Note to Installers

Section 2: User Commands7[][6] – User FunctionsPress [][6] followed by the Master Code, then press the number corresponding to the following functio