PC5O15Version 2.2DLS-3 version 1.3 or higherWWWWWARNINGARNINGARNINGARNINGARNING This manual contains information on limitations regarding pro
G E T T I N G S T A R T E D7Connect the PC5015 and modules that use the telephone line(s) in the following order:For example, if you are installing a
G E T T I N G S T A R T E D8BELL: 700 mA. Continuous Rating.3.0 A. Short Term. Available only with stand-by battery connected.• PC5200/5204 VAUX:1.0
G E T T I N G S T A R T E D92.7 Keypad AssignmentThere are 8 available addresses for keypads. The LED, LCD5501Z and the LCD5501Z32-433 keypads by def
G E T T I N G S T A R T E D102.9 Removing ModulesIf a module is no longer required on the system the panel must be told to no longer supervise the mo
G E T T I N G S T A R T E D11The following chart shows zone status under certain conditions:Loop Resistance Loop Status0Ω (shorted wire, loop shorted
G E T T I N G S T A R T E D122.10.8 LINKS Supervisory (24 Hour Supervisory)When using the LINKS1000 cellular communicator, any main board zone maybe
Keypad CommandsS E C T I O N 313All keypads provide complete information and control of the alarm panel. The panel can be completely programmedvia an
K E Y P A D C O M M A N D S14system was not Ready. When the correct code is entered and the system is Ready the panel will beep six timesrapidly and
K E Y P A D C O M M A N D S15The various troubles are described below:Light Trouble1 Service Required: Press [1] to determine the specific trouble. I
K E Y P A D C O M M A N D S16[✱✱✱✱✱] [5] Programming Access CodesAll 37 access codes are programmed in this section. For instructions on programming
LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelve months fromthe date of purchase, the produc
K E Y P A D C O M M A N D S17[✱✱✱✱✱] [0] Quick ArmIf the Quick Arm Enable option is enabled the panel can be armed by entering [✱][0]. This is a usef
K E Y P A D C O M M A N D S18[06] - [✱]+[4] Door Chime On/OffThis function key provides the user a simple method for turning the Door Chime feature o
K E Y P A D C O M M A N D S19[24] - Recall Bypass Group #1This function key will recall zones in Bypass Group #1. This group is programmed by the use
How to ProgramS E C T I O N 420The following section of the manual describes how to enter Installer Programming and how to program the varioussection
H O W T O P R O G R A M21Example: for the three digit account number ‘403’, you would enter [4], [✱] [1] [✱] [3], [0].[4] to enter the digit 4[✱] to
Program Descriptions22S E C T I O N 5The following section explains all the programmable features including how the feature operates, options thatper
P R O G R A M D E S C R I P T I O N S23[09] 24 Hour Supervisory Zone If this zone is violated, whether armed or disarmed, the panel will report to t
P R O G R A M D E S C R I P T I O N S24Force Arm Enable Determines if the system can be armed with the zone violated. At the end of exit delay, if
P R O G R A M D E S C R I P T I O N S251st Phone Number ... Section [301]2nd Phone Number ...
P R O G R A M D E S C R I P T I O N S26Please refer to Appendix A: “Reporting Codes”for a list of Contact ID Identifiers.Contact ID Uses Programmed/A
Table of ContentsSection 1: Introduction1.1 PC5015 Specifications ... 11.2 Additional Devices ..
P R O G R A M D E S C R I P T I O N S275.7 Communicator – Reporting CodesReporting codes must be programmed in order for the panel to report events t
P R O G R A M D E S C R I P T I O N S28on the Bell Output of the main panel. The Bell Circuit Trouble Restoral Reporting Code will be transmitted ass
P R O G R A M D E S C R I P T I O N S29The time to complete a successful download can be significantly reduced with the use of the PC-Link. This adap
P R O G R A M D E S C R I P T I O N S30Please refer to the Control Panel Wiring Diagram in this manual for wiring instructions.Only ONE of options [0
P R O G R A M D E S C R I P T I O N S31[15] Remote Operation (DLS-3 Support) This output can be activated and deactivated remotely using DLS soft
P R O G R A M D E S C R I P T I O N S32PGM Output Attributes ... Section [141]-[142]PC5208 Attributes ...
P R O G R A M D E S C R I P T I O N S33Test Transmission Reporting Codes ... Section [352]Test Transmission Time of Day ...
P R O G R A M D E S C R I P T I O N S34exists. (See Section 5.17 “Swinger Shutdown”.)The event buffer can be viewed three different ways. It can be v
P R O G R A M D E S C R I P T I O N S35Arm/Disarm Bell Squawk ... Section [014], Option [1]Bypass Status Display
P R O G R A M D E S C R I P T I O N S365.23 Keypad BlankingIf the Keypad Blanking Option is enabled the panel will turn off all lights and LCDs o
1System IntroductionS E C T I O N 11.1 PC5015 SpecificationsFlexible Zone Configuration:• 8 Fully Programmable Zones• 38 Access Codes: 32 User, 1 Sys
P R O G R A M D E S C R I P T I O N S375.26.4 LINKS Special PreambleIn some areas of North America, dialing #DAT or ✱DATA reduces the cellular billin
P R O G R A M D E S C R I P T I O N S385.28.2 Factory Default Main Panel (Software) and other ModulesStep 1 - Enter Installer Programming.Step 2 - En
SIA Format (Level 2—Hardcoded)This format will send the Account Code along with itsdata transmission. At the receiver, the transmissionwould look simi
40REPORTINGV CODESSection#Reporting Code Code Sent When... DialerDirection*Auto-maticContactIDSIA AutoRepCodes**[344-348]Openings system disarmed (use
41Zone Definition SIA Auto RepCodes**Delay, Instant, Interior, DelayStay/Away, Interior Stay/Away,24-hr Burg.BA-ZZ/BH-ZZStandard 24-hr Fire, Delayed 2
42PC5015 Control Panel Wiring DiagramAPPENDIXV C
Modules Supported on the PC5015 v2.2APPENDIXV DeludoMdetroppuSstnemmoC0855trocsEseY4025CPseY8025CPseY8015CPseYL8015CPseYX.1v2315CPseYsdapyeKdlehdnaHro
FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use th
©2002 Digital Security Controls Ltd.Toronto, Canada • www.dsc.comTechnical Support: 1-800-387-3630Printed in Canada 29003272 R005Direct all comme
S Y S T E M I N T R O D U C T I O N2False Alarm Prevention Features• Audible Exit Delay • Audible Exit Fault • Urgency on Entry Delay• Quick Exit • S
S Y S T E M I N T R O D U C T I O N31.2.4 PC5200/PC5204 Power Supply Output ModuleThe PC5200 and PC5204 can provide up to 1 Amp of additional power f
S Y S T E M I N T R O D U C T I O N41.2.11 PC5700 Fire ModuleThis is a zone expansion module with four general purpose zone inputs, two Class Asuperv
Getting StartedS E C T I O N 25The following sections provide a complete description of how to wire and configure devices and zones.2.1 Installation
G E T T I N G S T A R T E D6Auxiliary Power Terminals - AUX+ and GNDThese terminals provide up to 550 mA of additional current at 12 VDC for devices