31
P R O G R A M M I N G W O R K S H E E T S
[006] Installer’s Code (Section 4.1 “Installer Programming”)
Default: 5008 I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes”)
Default: 1234 I_______I_______I_______I_______I
[008] Maintenance Code (Section 5.1 “Programming Security Codes”)
Default: AAAA I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.11 “PGM Output Options”)
Programmable Output Options
01 Burglary and Fire Bell Output 13 Kissoff Output
02 For Future Use 14 Ground Start Pulse
03 Sensor Reset 15 Remote Operation (DLS-1 Support)
04 For Future Use 16 LINKS 1000 Support (PGM1 only)
05 System Armed Status 17 Away Armed Status
06 Ready To Arm 18 Stay Armed Status
07 Keypad Buzzer Follow Mode 19 Command Output #1 ([✱] [7] [1])
08 Courtesy Pulse 20 Command Output #2 ([✱] [7] [2])
09 System Trouble Output (with Trouble options) 21 Command Output #3 ([✱] [7] [3])
10 System Event [Strobe (with Event options)] 22 Command Output #4 ([✱] [7] [4])
11 System Tamper (all sources: zones, kpd, modules) 23 Silent 24 Hour (PGM2 Only)
12 TLM and Alarm 24 Audible 24 Hour (PGM2 Only)
Output types [03] and [20] cannot be used together on the same system.
Default Default
19
I_______I_______I PGM 1 10 I_______I_______I PGM 2
Program PGM Option Attributes in sections [141] & [142].
[010] PC5208 PGM Output Programming (PGM 3-10)
(Section 5.11 “PGM Output Options”)
Default Default
01
I_______I_______I PGM 3 01 I_______I_______I PGM 7
01
I_______I_______I PGM 4 01 I_______I_______I PGM 8
01
I_______I_______I PGM 5 01 I_______I_______I PGM 9
01
I_______I_______I PGM 6 01 I_______I_______I PGM 10
[011] PC5204 PGM Output Programming (PGM 11-14)
(Section 5.11 “PGM Output Options”)
Default Default
01
I_______I_______I PGM 11 01 I_______I_______I PGM 13
01
I_______I_______I PGM 12 01 I_______I_______I PGM 14
Program PGM Option Attributes in sections [141] - [154].
[012] Keypad Lockout Options
(Section 5.21 “Keypad Lockout Options”)
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
Default Option ON OFF Section
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors 2.8
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8
ON
I________I 3* Panel shows all troubles when armed Panel shows only Fire troubles when armed 3.4
OFF
I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open 3.4
OFF
I________I 5 For Future Use
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 5.18
ON
I________I 7
Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 5.20
OFF I________I 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal 5.13
* Option 3 must be OFF if LCD keypads older than v2.0 are used.