DSC Power608 Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 3
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
3
18) With the Armed light illuminated remove one leg of the resistor installed between zone
1 and COM. The entry warning tone will be generated by the keypad. Let the entry
timer time out, causing the unit to go into alarm.
19) With the meter set to 20 volts DC place the meter across the Bell + an – terminals, the
meter should read between 12 to 13.8 volts.
Next place the meter across the strobe output (PGM1 for the PC585, PC1565 and
Power 608 and PGM2 for the Power 832) and + AUX, again the meter should read
between 12 to 13.8 volts.
If either of these 2 outputs do not read 12 to 13.8 volts under an alarm condition then
the output transistors may have been damaged and the unit should be returned to
DSC for repair.
20) Now replace the resistor into the terminal, an alarm and restoral report (134) for zone 1
should have been transmitted to the central station.
21) Disarm the system by entering the master code [1234]. Check that the bell output and
strobe outputs have returned to normal (around 1.5 volts for the bell and 0.5v for the
strobe). A disarm signal 402 for user 1 should be transmitted to the central station.
These steps have tested the basic operating functions of the unit – After completion
reset the panel to factory settings
To test a keypad for functionality, connect the keypad to a control panel and:
1) Check that each zone LED is illuminated
2) Check each button by depressing the button and ensure that it beeps
3) Check the Bypass LED by bypassing the zones, enter [*1] and then each zone number
(ie 01, 02, 03 etc) and then press the [#] button.
4) The Green Ready LED and the bypass (or system) LED should be illuminated.
5) Arm the system to test the red armed LED.
6) Test that the function buttons are operating correctly.
In some cases it may be found that the keypad has accidentally been programmed as a
partition 2 keypad when it is connected to a single partition system. This causes the keypad
to appear “dead” and also the trouble (system) LED is illuminated.
To reprogram the keypad to partition 1:
1) Press the [#] button on the keypad for about 3 seconds and the keypad should beep a
number of times then press the number [1] button on the keypad. This should temporally
enrol the keypad on partition 1
2) Enter programming mode [*8] [installer code] and then enter keypad programming
[000]
3) When in keypad programming enter a further [0] (keypad ‘slot”programming) and then
enter [11] (for keypad 1 on partition 1).
4) Escape out of programming [#] [#].
Vista de pagina 2