34
PC3000 Version 7.51
[51] 3rd System Option Code Page 23
Default Zone Light On Zone Light Off
On Zone Light 1 ..................Auto-arm - no bell squawk Auto-arm - bell squawk
Off
Zone Light 2 ..................Code needed to abort auto-arm Any key to abort auto-arm
Off
Zone Light 3 ..................2 minute timeout on keypad No 2 minute timeout
Off
Zone Light 4 ..................Keypad panic buzzer silent Keypad panic buzzer audible
Off
Zone Light 5 ..................Keypad fire key disabled Keypad fire key enabled
Off
Zone Light 6 ..................Quick exit enabled Quick exit disabled
Off
Zone Light 7 ..................Answering machine over-ride Answering machine over-ride
timer = 120 seconds timer = 60 seconds
Off
Zone Light 8 ..................Bell shutdown active Bell shutdown not active
[52] Delay Before Transmission Page 23
Default
0 0 = No delay Only burglary zones are delayed. All 24 hour and fire zone transmit immediately.
If panel is disarmed before delay time, no transmission is sent.
Valid entries are: 00 to 99 (in seconds).
[53] Auto-arm Abort Reporting Code Page 23
Entering a valid reporting code will enable this feature.
[54] System Test Reporting Code Page 23
Entering a valid reporting code will enable this feature.
[90] Installer’s Lockout Enable Page 23
[91] Installer’s Lockout Disable Page 23