NOTES ON UL INSTALLATION
This equipment is UL Listed in accordance with standard UL1023 (Household Burglar - Alarm
System Units), standard UL985 (Household Fire Warning Units), UL1635 (Digital Alarm
Communicator System Units), standard UL365 (Police Station Connected Burglar Alarm Units
and Systems), standard UL609 (Local Burglar Alarm Units and Systems), and standard UL1610
(Central Station Burglar Alarm Units).
This equipment has the capability of being programmed for operational features that are not
allowed for UL Listed installations. To stay within the standard for household applications, the
installer should use the following guidelines when configuring the system.
1. ALL components of the system should be UL Listed for the intended application. Note
elsewhere in this manual, recommendations for smoke detectors and battery to be used
with this equipment.
2. If this system is configured for “Fire”, the installer should refer to NFPA Standards #74 for
details on locating smoke detectors. When the “Fire” feature is enabled, there must be at
least one UL Listed indoor Fire Alarm Warning Signaling Appliance.
3. Residential fire and burglary systems:
Maximum allowed entry time = 45 seconds
Maximum allowed exit time = 60 seconds
Minimum allowed bell cutoff time = 4 minutes
4. The “Split Arming” feature is not allowed for UL Listed installations. The equipment must be
configured as a single system.
5. User bypass must be enabled so that a user code is required to bypass zones.
6. The installer should caution the user to NOT give system information to casual users. E.g.
Codes, bypass methods, etc. to babysitters or home service people. Only the “One-Time”
use code should be given to the casual user.
7. The installer should advise the user and note in the user manual:
Service organization name and telephone number
The programmed exit time
The programmed entry time
8. Remote programming must be disabled.
9. Grade A Local Mercantile Alarm Unit Installations
Listed Grade A bell Model AMSECO MBL10B and bell housing Model AB-12.
Alarm enclosure Model CMC-1, with door tamper.
Maximum 60 seconds of exit and entrance delays.
Provision is made for bell test upon arming.
Use of integral DACT (Digital Alarm Communicator Transmitter).
10.Grade A Police Station Connected Burglar Alarm Installations
Same as Grade A Local Mercantile Alarm Unit Installations with the following addition:
An audible ringback indication is provided at the keypad to indicate completion of the
closing signal transmission to the digital alarm communicator receiver.
11.Grade B Central Station Alarm Unit Installations
Same as Grade A Local Mercantile Alarm Unit Installations and Grade A Police Station
Connected Burglar Alarm Installations.
12.Grade C Central Station Alarm Unit Installations
Same as Grade B Central Station Alarm Unit Installations with the following exception: the
bell and listed Model CMC-1 alarm housing is not required.
13.Grade A Residential Burglary Warning System
14.Household Fire Warning System