PC4400 Serial Interface Module
True RS-232 technology
Handshake software switches
Protocol XON/XOFF or DTR
5 possible baud rates 300, 600, 1200, 2400 and 4800
DVAC communications
Four wire (QUAD) hook-up to Combus
Nominal current draw of 35 mA
Provides Tamper Reporting Codes
Low Combus supervision to PC4020 Main Board
Note: 4800 Baud is only available on PC4400 software
version 2.00 and above.
PC4700 Fire Module
One module per system
2 wire Class B/Style B smoke detector circuit (20
detectors maximum)
4 wire Class D/ Style D waterflow circuit (5 sensor
maximum [NFPA 3-8-6-3])
1 fully programmable supervised bell output.
(Controlled via the Main Bell Output)
Dual supervised Telco lines - With the ability to switch
to the second line in the event of a line failure.
Ground fault detection
Nominal current draw of 35 mA
Four wire quad connection to Combus
Low Combus supervision to the Main Board
Reporting codes for:
- Bell CCT Trouble
- Waterflow Alarm/Trouble
- 2 Wire smoke Alarm/Trouble
- TLM trouble/restoral for line 1 and line 2
- Ground Fault
LCD4500 Remote Keypad
Up to 16 keypads on system
Alphanumeric liquid crystal display
Built-in piezoelectric buzzer
Full annunciation of zones and system status
Four wire (QUAD) hook-up to Combus
Nominal current draw of 55 mA
Provides Tamper Reporting Codes
Low Combus supervision to PC4020 Main Board
Dimensions 5.75" x 4.5" x 1" deep (144 x 114 x 25 mm)
Escort4580 (Voice Prompting Module)
One module per system
Full voice prompts for all major user accessible
sections
Four wire quad connection to Combus
Nominal current draw of 70 mA - 140 mA
Automation Control capabilities - up to 32 Automation
Module per system
Low Combus supervision to the main board
PC4108 Expansion Module
Up to 128 zones total on system
8 zone expansion module
Normally closed loops, EOL resistor, Double EOL
resistor support
Four wire (QUAD) hook-up to Combus
Nominal current draw of 25 mA
Provides Tamper Reporting Codes
Low Combus supervision to PC4020 Main Board
PC4116 Expansion Module
Up to 128 zones in total on system
Normally closed loops, EOL resistor, Double EOL
resistor support
16 zone expansion module
Four wire (QUAD) hook-up to Combus
Nominal current draw of 30 mA
Provides Tamper Reporting Codes
Low Combus supervision to PC4020 Main Board
PC4164 Expansion Module
Up to 64 zones in total on the system
One module per system
64 zone wireless expansion module
Support for Universal transmitters and PIRs
Normally closed and zone module tamper support
4 wire quad hookup to the PC4164
Nominal current draw of 110 mA
Provides zone alarm/zone low battery/zone tamper
reporting codes
Low Combus supervision to the PC4020
PC4204 High Current Output Module
4 output high current module
Up to 16 modules on system
Minimum 40 VA 16-18 volt transformer required
Minimum 4 Amp-Hour, 12 volt battery required
Each output programmable for 1 of 35 options
Four wire (QUAD) hook-up to Combus
Nominal current draw of 25 mA
Provides Tamper and Trouble Reporting Codes
Low Combus supervision to PC4020 Main Board
1.5 Amp output
PC4216 Low Current Output Module
16 output low current module
Up to 9 modules on system
All module programmable for all 16 outputs, 1 of 35
options for each
Programmable as alarm annunciators or zone followers
Four wire (QUAD) hook-up to Combus
Nominal current draw of 15 mA
Provides Tamper Reporting Codes
Low Combus supervision to PC4020 Main Board
MODULE
SPECIFICATIONS