28
[073] Downloaded LCD Message Duration
Default: 003
I_______I_______I_______I (Valid entries are 000-255, 000=Unlimited Message Display. This number represents the number of
times the Downloaded message is cleared by pressing any key while the message is up after timeout)
[074] Key Options
Default Option ON OFF
ON
I_______I 1 [F]ire Keys enabled [F]ire Keys disabled
ON
I_______I 2 [A]uxiliary Keys enabled [A]uxiliary Keys disabled
ON I_______I 3 [P]anic Keys enabled [P]anic Keys disabled
OFF
I________I 4-8 For Future Use
[075] Fourth User Display Mask
Default Option ON OFF
ON
I_______I 1 User Initiated Call-up prompt ON User Initiated Call-up prompt OFF
OFF
I_______I 2 Last Code to Disarm/Arm prompt ON Last Code to Disarm/Arm prompt OFF
OFF
I _______I 3 Walk Test Prompt ON Walk Test Prompt ON
ON
I_______I 4 Command Output #1 prompt ON Command Output #1 prompt OFF
ON
I_______I 5 Command Output #2 prompt ON Command Output #2 prompt OFF
OFF
I_______I 6 Command Output #3 prompt ON Command Output #3 prompt OFF
OFF
I_______I 7 Command Output #4 prompt ON Command Output #4 prompt OFF
OFF
I_______I 8 For Future Use
[076] Keypad Options
Default Option ON OFF
ON I_______I 1 Display Access Code when Programming Display ‘X’ when Programming
ON
I_______I 2 Local Clock Display Enabled Local Clock Display Disabled
OFF
I_______I 3 Local Clock Displays 24 Hour time Local Clock Displays AM/PM
ON
I_______I 4 Auto Alarm Memory Scroll Enabled Auto Alarm Memory Scroll Disabled
OFF
I_______I 5 Local Display of Temperature Enabled* Local Display of Temperature Disabled
OFF
I_______I 6 Bypass Options prompt ON Bypass Options prompt OFF
OFF
I_______I 7 For Future Use
OFF
I_______I 8 Auto Scroll Open Zones Enabled Auto Scroll Open Zones Disabled
[077] Fifth User Display Mask
Default Option ON OFF
OFF
I_______I 1 Thermostat CTRL Prompt ON* Thermostat CTRL Prompt OFF
OFF
I_______I 2 Temperature Setting Prompt ON* Temperature Setting Prompt OFF
OFF
I_______I 3 Occupancy Mode Prompt ON* Occupancy Mode Prompt OFF
OFF
I_______I 4 Thermostat Mode Prompt ON* Thermostat Mode Prompt OFF
OFF
I_______I 5 Fan Control Prompt ON* Fan Control Prompt OFF
OFF
I_______I 6 For Keypad View Prompt ON* For Keypad View Prompt OFF
OFF
I_______I 7-8 For Future Use
[078] Sixth User Display Mask
Default Option ON OFF
OFF
I_______I 1 Occupancy Mode Auxiliary Prompt ON* Occupancy Mode Auxiliary Prompt OFF
OFF
I_______I 2 Occupancy Mode Day Prompt ON* Occupancy Mode Day Prompt OFF
OFF
I_______I 3 Occupancy Mode Away Prompt ON* Occupancy Mode Away Prompt OFF
OFF
I_______I 4 Occupancy Mode Night Prompt ON* Occupancy Mode Night Prompt OFF
OFF
I_______I 5-8 For Future Use
NOTE: These options are only relevant if you are using LCD5500Z v2.1 or higher or LCD5520Z v3.1 and higher keypads.
Partition Labels
Default: “System” - “Partition 2”
Section Partition Label
[101] 1/System
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[102] 2 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
Comentarios a estos manuales