5
System Times and Codes
[005] System Times
[006] Installer’s Code
Default
5555
I_______I_______I_______I_______I
[007] Master Code
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code
Default
AAAA
I_______I_______I_______I_______I
Programmable Output Options
01 Residential Burglary and Fire Bell Output 14 Ground Start Pulse
02 For Future Use 15 Remote Operation (DLS2002 Support)
03 Sensor Reset [*][7][2] 16 LINKS1000 Support (PGM1 only)
04 2 Wire Smoke Support (PGM 2 only) 17 Away Armed Status
05 System Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 ([*][7][1])
07 Keypad Buzzer Follow Mode 20 Command Output #2 ([*][7][2])
08 Courtesy Pulse 21 Command Output #3 ([*][7][3])
09 System Trouble Output (with Trouble options) 22 Command Output #4 ([*][7][4])
10 System Event [Strobe (with Event options)] 23 24 Hour Silent Input
11 System Tamper (all sources: zones, keypad, modules) 24 24 Hour Audible Input
12 TLM and Alarm 25 Delayed Fire and Burglary Output
13 Kissoff Output
NOTE: Output types [03] and [20] cannot be used together on the same system.
[009] PGM1 and PGM2 Output Programming (Main Panel)
NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
19 I_______I_______I
PGM 1 10
I_______I_______I
PGM 2
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208)
NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
01
I_______I_______I
PGM 3 (main panel/PC5208)* 01
I_______I_______I
PGM 7 (PC5208)
01
I_______I_______I
PGM 4 (main panel/PC5208)* 01
I_______I_______I
PGM 8 (PC5208)
01
I_______I_______I
PGM 5 (PC5208) 01
I_______I_______I
PGM 9 (PC5208)
01
I_______I_______I
PGM 6 (PC5208) 01
I_______I_______I
PGM 10 (PC5208)
NOTE: These two sections allow you to program the first two PGM outputs on the PC5208.
[011] PGM11 to PGM14 Output Programming (PC5204)
NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
01
I_______I_______I
PGM 11 01
I_______I_______I
PGM 13
01 I_______I_______I
PGM 12 01
I_______I_______I
PGM 14
NOTE: Valid entries for Entry Delay is between 030-240, valid entries for Exit Delay is between 045-255.
[01] Partition 1 Entry/Exit times
030
I___I___I___I Entry Delay 1
030
I___I___I___I Entry Delay 2
060
I___I___I___I Exit Delay
[02] Partition 2 Entry/Exit times
030
I___I___I___I Entry Delay 1
030
I___I___I___I Entry Delay 2
060
I___I___I___I Exit Delay