P R O G R A M D E S C R I P T I O N S
29
The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output is
shorted. The AUX output control incorporates a fuseless design. When excessive current is drawn the
panel will automatically shut off the output. The panel will constantly check the AUX output and when the
excessive current draw is removed the panel will reset the output and transmit an Auxiliary Power
Supply Trouble Restoral Reporting Code.
A TLM Trouble Reporting Code can only be transmitted if a LINKS1000/2X50 Communicator is being
used
(See Section 5.26 “LINKS1000 Cellular Communicator”)
. The panel will only transmit the signal after
the time programmed for the TLM Trouble Delay. The TLM Restoral Reporting Code will be transmitted
immediately once the trouble is restored.
A General System Trouble Reporting Code will be transmitted if the panel detects any of the following on
the PC5204 Power Supply/Output Module: AC Power Failure, Low Battery, AUX Output Trouble, Output #1
Supervisory trouble. The General System Trouble Restoral Reporting Code will be transmitted when all
of the listed problems are corrected.
A General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing
from the Keybus. If the module is a zone expander the panel will also transmit the Zone Expander
Supervisory Alarm Trouble Reporting Code. The panel will send a General System Supervisory
Restoral Reporting Code when the problem is corrected as well as a Zone Expander Supervisory
Restoral Reporting Code if the module is a zone expander.
5.7.8 Test Transmissions
The panel can be programmed to transmit a Periodic Test Transmission
Reporting Code
(See Section
5.13 “Test Transmissions”)
, a System Test Reporting Code
(See Section 3.4 “[
] Commands, [
] [6]”)
or a
LINKS1000 Test Transmission Reporting Code
(See Section 5.26 “LINKS1000 Cellular Communicator”).
5.7.9 Wireless Maintenance
The panel will transmit a General Zone Low Battery Alarm Reporting Code if a low battery condition is
indicated by a detector. The transmission of the trouble will be delayed by the number of days
programmed for Zone Low Battery Transmission Delay. The General Zone Low Battery Restoral
Reporting Code will be transmitted when the problem is corrected. The specific zone that caused the
trouble will be stored to the Event Buffer.
The restoral will not be transmitted until all detectors indicate a good battery condition.
5.7.10 Miscellaneous
The panel will transmit the Keypad Lockout Reporting Code if the lockout is activated
(See Section 5.22
“Keypad Lockout”)
.
The DLS Lead In Reporting Code will only be transmitted if the DLS Call Back feature is being used
(See
Section 5.8 “Downloading”)
. Before the panel calls the computer back it will call central station and transmit
the reporting code to indicate a download session is about to begin. After downloading is complete the
panel will transmit a DLS Lead Out Reporting Code to indicate the download session is complete.
If the panel fails to transmit information to the central station it will display a failure to communicate trouble
condition. The panel will transmit a Phone Number 1 Failure to Communicate Reporting Code or a
Phone Number 2 Failure to Communicate Reporting Code the next time it calls the central station. The
panel will transmit the old events, followed by the failure to communicate, followed by the new events.
This will allow central station to determine which events are old or new.
If the Event Buffer is uploaded on a regular basis an Event Buffer 75% Full Reporting Code can be
transmitted to warn the Buffer is almost full. This is also useful if the PC5400 Printer Module is being used.
The Delinquency reporting code is sent whenever the panel is not armed within the number of days
programmed for the Delinquency Transmission Delay.
If the Delinquency Transmission Delay is set for one day, there must be 24 hours of no arming or disarm-
ing before the Delinquency Code will be sent.
After a Delinquency Code has been transmitted, it will not send again until the system has been armed
and disarmed.
5.7.11 Activity Delinquency
When Delinquency Follows Zone Activity is enabled, if there is no activity on zones in the system, the
Delinquency Transmission Cycle Timer in Section [370] will begin counting in hours. When the counter
reaches the programmed time, the panel will communicate the Delinquency reporting code to the central
station, if programmed. If there is zone activity present on the system at any time, the counter will be
reset. If this option is used, the Delinquency Follows Arming option is not available.
Activity Delinquency will not be reported while the panel is armed in Away mode.
Activity on bypassed zones will not reset the timer. PGM2 activation will not reset the timer.
This timer is reset when the panel is armed, or if Installer Programming is entered.
When using the SIA FSK communication format with Activity Delinquency, the Closing Delinquency
identifier is transmitted.