P R O G R A M D E S C R I P T I O N S
36
5.19 Keypad Backlighting
The keys of all the keypads can be backlit to provide easy viewing in dim lighting conditions. If the
Keypad Backlighting Option
is enabled the keys will be illuminated.
Keypad Backlighting Option ................................... Section [016], Option [5]
5.20 Arming /Disarming Options
If the Arm/Disarm Bell Squawk option is enabled the panel will squawk the alarm output once upon
arming and twice upon disarming. The Opening After Alarm Keypad Ringback option will give you the
ability to beep the keypad 10 times rapidly if the panel is disarmed after an alarm occurred. The Opening
After Alarm Bell Squawk
option will give you the ability to squawk the bell output 10 times rapidly if the
panel is disarmed after an alarm occurred.
Closing Confirmation, if enabled, will cause the keypad to beep 10 times rapidly after the closing
reporting code has been successfully transmitted to central station.
If the Bypass Status Displayed While Armed option is chosen, the Bypass light will be ON while the
system is armed to indicate that there are bypassed zones.
Arm/Disarm Bell Squawk ....................................... Section [014], Option [1]
Opening After Alarm Keypad Ringback ................. Section [381], Option [1]
Opening After Alarm Bell Ringback ....................... Section [381], Option [2]
Closing Confirmation .............................................. Section [381], Option [4]
5.21 Automatic Arming
Each Partition can be programmed to Auto-Arm at a specific time every day if it is in the disarmed condition.
Before the Auto-Arm will work correctly the present Time of Day
must be programmed.
When the internal panel clock matches the Auto-Arm Time
the panel will check the status of the Partition.
If armed, the panel will do nothing until the next day at the Auto-Arm Time, when it will check again.
If disarmed the panel will sound the buzzer of all keypads assigned to the partition for one minute. If a
valid User Code is entered the Auto-Arm will be aborted. The panel will also transmit an Auto-Arm Abort
Reporting Code
if programmed.
If no code is entered the panel will Auto-Arm. If a zone is violated the panel will transmit a Partial Closing
Reporting Code
if programmed to indicate the system was not secure. If the zone is restored the panel
will add the zone back into the system.
Time Date................................................................ 3.4 [] Commands, [][6][1] Time and Date
Auto-Arm Time ........................................................ 3.4 [] Commands, [][6][3] Auto-Arm Time
Auto-Arm Cancel Reporting Code ......................... Section [348]
Partial Closing Reporting Code ............................. Section [343]
5.22 Keypad Lockout
The panel can be programmed to ‘lockout’ keypads if a series of incorrect access code entries are made.
After the Number of Invalid Codes Before Lockout has been reached the panel will lock out the keypad
for the Lockout Duration
and log the event to the event buffer. For the duration of the lockout the panel
will sound an error tone when any key is pressed.
The invalid code counter will be reset every hour.
To disable Keypad Lockout program the Number of Invalid Codes Before Lockout
as [000].
If Keypad Lockout is active, the panel cannot be armed/disarmed with a keyswitch.
Number of Invalid Codes Before Lockout .............. Section [012]
Lockout Duration ..................................................... Section [012]
Keypad Lockout Reporting Code ........................... Section [338]
5.23 Keypad Blanking
If the Keypad Blanking Option
is enabled the panel will turn off all lights and LCDs on the keypads if no
key is pressed for 30 seconds. The keys, however, will remain backlit.
The panel will turn the lights and LCDs back on if entry delay begins or an audible alarm occurs. The
lights and LCDs will also come on if a key is pressed or, if the Code Required to Restore Blanking
Option
is enabled, a valid User Code is entered.
If the Power Save Option
is enabled the panel will blank all keypad lights including backlighting when
AC power fails, in order to conserve the back up battery.
Keypad Blanking Option ......................................... Section [016], Option [3]
Code Required to Restore Blanking ...................... Section [016], Option [4]
Power Save Option ................................................. Section [016], Option [6]