Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using the
standard (non-automatic) Contact ID reporting format.
Table 3: SIA Format Automatic Zone
Alarm/Restoral Codes
Section # Reporting Code Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
[345]-[346] AC Line Trouble/Rest. AC power to control panel is disconnected or interrupted/
AC power restored (Both codes follow AC Failure Comm.
Delay.)
MA/R (3) A1 AT-00/AR-00
[345]-[346] Bell Circuit Trouble/Rest. open or short circuit detected across bell terminals/bell cir-
cuit restored
MA/R (3) 21 UT-99/UJ-99
[345]-[346] Fire Trouble/Rest. a trouble occurs/restores on a fire zone MA/R (3) 73 FT-00/FJ-00
[345]-[346] Auxiliary Power Trouble/Rest. aux voltage supply trouble/restoral MA/R (3) AA YP-00/YQ-00
[345] TLM Failure telephone line monitoring trouble (sent via LINKS1000. Do
not program if LINKS1000 not used)
MA/R (3) 51 LT-00
[346] TLM Restore Telephone line restored MA/R (3) 51 LR-00
[345]-[346] Gen System Trouble/Rest. “Service Required” trouble occurs (view troubles using
[*][2])/trouble restored
MA/R (3) AA YX-00/YZ-00
[345]-[346] Gen System Supervisory
Trouble/Rest.
control panel loses/restores communications with mod-
ule(s) connected to the Keybus
MA/R (3) 33 ET-00/ER-00
[347] Line 1 or 2 FTC Restoral control panel has restored communications to central sta-
tion on line 1 or 2 (after FTC)
MA/R (3) 54 YK-00
[347] Event Buffer is 75% Full event buffer is almost full since last upload MA/R (6) 23 JL-00
[347] DLS Lead In downloading session start MA/R (4) 11 RB-00
[347] DLS Lead Out downloading session complete MA/R (4) 12 RS-00
[347] Zone Fault/Rest. one or more zones have faults/restored MA/R (3) 72 UT-ZZ/UJ-ZZ
[347] Delinquency programmed amount of time (days or hours) for delin-
quency has expired without zone activity, or without system
being armed
MA/R (4) 54*** CD-00
[347] Wireless Device Low Battery
Trouble/Rest.
wireless zones, panic pendants, handheld keypads, wireless
keys have low battery/all low batteries restored
MA/R (3) 84 XT-00/XR-00
XT-ZZ/XR-ZZ****
[348] Periodic Test periodic system test transmission T (6) A2 RP-00
[348] System Test [*][6] bell/communications test T (6) A1 RX-00
[348] LINKS1000 Test LINKS1000 test transmission T (6) A3 TX-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-64)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency. Make sure your central station is aware of the applica-
tion of this reporting code.
****Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
Medical Alarms (1)34 Entry / Exit
(1)AA Medical (1)35 Day / Night
(1)A1 Pendant Transmitter (1)36 Outdoor
(1)A2 Fail to Report In (1)37 Tamper
Fire Alarms (1)38 Near Alarm
(1)1A Fire Alarm General Alarms
(1)11 Smoke (1)4A General Alarm
(1)12 Combustion (1)43 Exp. module failure
(1)13 Water Flow (1)44 Sensor tamper
(1)14 Heat (1)45 Module Tamper
(1)15 Pull Station (1)4A Cross Zone Police Code
(1)16 Duct 24 Hour Non-Burglary
(1)17 Flame (1)5A 24 Hour non-Burg
(1)18 Near Alarm (1)51 Gas detected
Panic Alarms (1)52 Refrigeration
(1)2A Panic (1)53 Loss of Heat
(1)21 Duress (1)54 Water Leakage
(1)22 Silent (1)55 Foil Break
(1)23 Audible (1)56 Day Trouble
Burglar Alarms (1)57 Low bottled Gas level
(1)3A Burglary (1)58 High Temp
(1)31 Perimeter (1)59 Low Temp
(1)32 Interior (1)61 Loss of Air Flow
(1)33 24 Hour
Zone Definition
SIA Auto Rep
Codes*
Zone Alm/Rest.
Delay, Instant, Interior, Delay Stay/
Away, Interior Stay/Away, 24Hr
Burg.
BA-ZZ/BH-ZZ
Standard 24Hr Fire, Delayed 24Hr
Fire
FA-ZZ/FH-ZZ
24Hr Supervisory US-ZZ/UR-ZZ
24Hr Supervisory Buzzer UA-ZZ/UH-ZZ
24Hr Sprinkler SA-ZZ/SH-ZZ
24Hr Gas GA-ZZ/GH-ZZ
24Hr Heat KA-ZZ/KH-ZZ
24Hr Medical MA-ZZ/MH-ZZ
24Hr Emergency (non-medical) QA-ZZ/QH-ZZ
24Hr Waterflow WA-ZZ/WH-ZZ
24Hr Freeze ZA-ZZ/ZH-ZZ
24Hr Holdup HA-ZZ/HH-ZZ
24Hr Panic PA-ZZ/PH-ZZ
Latching 24Hr BA-ZZ/BH-ZZ
* ZZ = zones 01-64