DSC PC5020 Manual de instalación Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
12
[190] No Activity Arming Pre-Alert Time
Default Partition Default
001 All I_______I_______I_______I Valid entries are 001-255 seconds, 000 for no pre-alert
No Activity Arming Timers
Section Partition Default
[191] 1 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[192] 2 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[193] 3 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[194] 4 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[195] 5 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[196] 6 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[197] 7 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
[198] 8 I_______I_______I_______I Valid entries are 001-255 seconds, 000 to disable
NOTE: Default is [000] for all partitions.
[199] Auto-arming Pre-Alert Timer
Default: 005
I_______I_______I_______I Valid entries are 001-255 seconds