Section 7: Downloading Options
[401] First Downloading Option Code
Default Option ON OFF
OFF
I_______I 1 Answering machine/double call enabled Answering machine/double call disabled
ON
I_______I 2 User Can Enable DLS Window User Cannot Enable DLS Window
OFF
I_______I 3 Call-Back Enabled Call-Back Disabled
OFF I_______I 4 User-initiated call-up enabled User-initiated call-up disabled
OFF
I_______I 5 Auto Event Buffer Upload Enabled Auto Event Buffer Upload Disabled
OFF
I_______I 6-8 For Future Use
[402] Downloading Computer’s Telephone Number (32 Digits)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[403] Downloading Access Code
Default: 5020
I_______I_______I_______I_______IEnter 4 HEX digits
[404] Panel Identification Code
Default: 5020
I_______I_______I_______I_______IEnter 4 HEX digits
[405] Answering Machine Double-call Timer
Default: 060
I_______I_______I_______I (Valid entries are 001-255 seconds)
[406] Number of Rings to Answer On
Default: 000
I_______I_______I_______I (Valid entries are 000-255 rings)
[490] LINKS Preamble (Downloading Telephone Number)
Default: FFFF
I_______I_______I_______I_______I (Program all unused digits with Hex F)
[499] Initiate PC-Link (Local Downloading)
To begin PC-Link downloading, enter [499][Installer’s Code][499].