9.1 Programming the System Using
Downloading Software
Another way to program the PC6010 system is by using a
computer and DLS-3 downloading software. You can enter the
programming data in the computer, and then use a modem, or a
PC-LINK module to send the data to the control panel. You can
do this over the telephone line with a remote computer, or at a
computer located on site.
Please see the DLS-3 manual for complete instructions on how to
install, set up and use the DLS-3 software. See the DLS Section
of the PC6010 Programming Manual for information on DLS-3
programming options.
9.2 Downloading over Telephone Lines
Make sure the “TIP” and “RNG” terminals are connected to the
telephone line. Program the downloading access code and the
panel I.D. code in the PC6010. Make sure that these codes are
also programmed correctly in the DLS-3 account file.
You can also set up downloading using the LINKS1000 module
as either a primary or backup communicator. See the “LINKS
Module” section in the Programming Manual for more
information.
You can set up the downloading so that the PC6010 will call the
computer, or have the computer call the control panel.
To have the control panel answer the telephone line when the
computer calls, you must enable either the “Ring Detect” or the
“Usr Allows Srv” downloading toggle options.
If you enable the Ring Detect option, the control panel will
always answer incoming telephone calls.
If you turn on the “Usr Allows Srv” downloading toggle option,
a Master user will have to answer YES to “Allow System
Service?” for the control panel to answer the telephone line. The
control panel will answer the telephone line for 60 minutes.
Master users will also have to Allow System Service before
Installer’s Programming is available at a system keypad.
If you enable both Ring Detect and Usr Allows Srv, the panel will
always answer telephone calls, but a Master user will still have to
Allow System Service, before the DLS-3 user or an installer can
access Installer’s Programming.
Section 9: Downloading
You can program the number of times the telephone line will
ring before the control panel answers it in the “# of Rings”
section. The default setting is 8 rings.
See the PC6010 Programming Manual for a complete
description of DLS Programming options.
9.3 PC-LINK
The PC-LINK module allows a direct connection between an on-
site computer and the control panel. With the PC-LINK, the
computer can communicate with the panel at 9600 baud. Use a
serial cable to link the computer with the control panel.
To download using PC-LINK:
1. Connect the PC-LINK connector to
the header on the PC6010 board,
as shown.
2. Enable PC-LINK in the Modem
Configuration section of the DLS-3
software. The software will display “PC-LINK Active” in the
Status Bar of the Communications window.
3. Open the appropriate account in the DLS-3, and select the
function to be performed (upload, download, etc.)
4. Go to any system keypad and enter Installer’s Programming
and select “System”, then “DLS Section”, then “Enable PC-
LINK”. The keypad displays the message “PC-LINK Active (#)
To Exit”.
5. Once the DLS communication is in progress, the panel will
automatically exit the Installer’s Programming mode.
6. When the desired DLS function(s) are complete, press the
hang-up button on the Communications window. This will
disconnect the DLS from the panel.
7. When you are finished, remove the PC-LINK connector from
the PC6010.
WARNING: Failure to remove the PC-Link connector from
the PC6010 after upload/download is complete will prevent
the panel from communicating successfully with the
monitoring station.