Programming Worksheets
31
[002] Zone 9-16 Definitions (Section 5.2 “Zone Programming” )
Default Default
00 I_______I_______I Zone 9 00 I_______I_______I Zone 13
00
I_______I_______I Zone 10 00 I_______I_______I Zone 14
00
I_______I_______I Zone 11 00 I_______I_______I Zone 15
00
I_______I_______I Zone 12 00 I_______I_______I Zone 16
[003] Zone 17-24 Definitions
(Section 5.2 “Zone Programming” )
Default Default
00
I_______I_______I Zone 17 00 I_______I_______I Zone 21
00
I_______I_______I Zone 18 00 I_______I_______I Zone 22
00
I_______I_______I Zone 19 00 I_______I_______I Zone 23
00
I_______I_______I Zone 20 00 I_______I_______I Zone 24
[004] Zone 25-32 Definitions
(Section 5.2 “Zone Programming” )
Default Default
00 I_______I_______I Zone 25 00 I_______I_______I Zone 29
00
I_______I_______I Zone 26 00 I_______I_______I Zone 30
00
I_______I_______I Zone 27 00 I_______I_______I Zone 31
00
I_______I_______I Zone28 00 I_______I_______I Zone 32
[005] System Times
Default Valid entries: [001-255]
030
I_______I_______I_______I Entry Delay 1 (in seconds)(Section 5.18 “Entry/Exit Delay Options” )
045 I_______I_______I_______I Entry Delay 2 (in seconds)(Section 5.18 “Entry/Exit Delay Options” )
120 I_______I_______I_______I Exit Delay (in seconds)(Section 5.18 “Entry/Exit Delay Options” )
004 I_______I_______I_______I Bell Cut-off (in minutes)(Section 5.13 “Bell” )
[006] Installer’s Code (Section 4.1 “Installer’s Programming” )
Default
5555 I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes” )
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code (Section 5.1 “Programming Security Codes” )
Default
AAAA I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.11 “PGM Output Options” )
Programmable Output Options
01 Burglary and Fire Bell Output 14 Ground Start Pulse
02 For Future Use 15 Remote Operation (DLS-1 Support)
03 Sensor Reset 16 LINKS1000 Support (PGM1 only)
04 2-wire smoke (50/300 only) 17 Away Armed Status
05 System Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 ([*][7][1])
07 Keypad Buzzer Follow Mode 20 Command Output #2 ([*][7][2])
08 Courtesy Pulse 21 Command Output #3 ([*][7][3])
09 System Trouble Output (with Trouble Options) 22 Command Output #4 ([*][7][4])
10 System Event [Strobe (with Event Options)] 23 Silent 24 Hour (PGM2 Only)
11 System Tamper (all Sources: Zones, Keypads, Modules) 24 Audible 24 Hour (PGM2 Only)
12 TLM and Alarm
13 Kissoff Output
NOTE: Output types [03], [04] and [20] cannot be used
together on the same system.
Default Default
19 I_______I_______I PGM 1 10 I_______I_______I PGM 2 Program PGM Option Attributes in sections [141] & [142].