Programming Worksheets
33
[015] Third System Option Code
Default Option ON Off Section
ON
I________I 1 Fire Keys Enabled Fire Keys Disabled 5.16
OFF I________I 2 Panic Keys Audible (Bell / Beeps) Panic Keys Silent 5.16
OFF
I________I 3 Quick Exit Enabled Quick Exit Disabled 3.4
ON*
I________I 4 Quick Arming Enabled Quick Arming Dis. / Function Keys Req. Code 3.4
OFF I________I 5 Code Required For Bypassing No Code Required 3.4
OFF
I________I 6 Master Code Not Changeable Master Code Changeable 5.1
ON I________I 7 TLM Enabled TLM Disabled 5.12
OFF I________I 8 TLM Audible (Bell) When Armed TLM Trouble Beeps When Armed 5.12
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
Default Option ON Off Section
ON I________I 1 AC Trouble Displayed AC Trouble Not Displayed 3.4
OFF
I________I 2 Trouble Light Flashes if AC Fails Trouble Light Does Not Follow AC Status 3.4
OFF
I________I 3 Blank Keypad When Not Used Keypad Active Always 5.22
OFF
I________I 4 Code Required to Remove Kypd BlankingNo Code Required 5.22
ON
I________I 5 Keypad Backlighting is Enabled Keypad Backlighting is Disabled 5.23
OFF
I________I 6 Power Save Mode Enabled Power Save Mode Disabled 5.22
OFF
I________I 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed 5.17
OFF
I________I 8 Keypad Tampers Enabled Keypad Tampers Disabled 5.25
[017] Fifth System Option Code
Default Option ON Off Section
ON
I________I 1 WLS Key Does Not Use Access Codes* WLS Key Uses Access Codes 5.17
OFF
I________I 2-7 For Future Use
OFF
I________I 8 Squawk on Away Arming/Disarming OnlyBell Squawk on all Arming/Disarming 5.17
NOTE: *This option must be enabled when using a PC5132
v2.1 or earlier.
[020] Keypad Zone Assignments
(Section 2.13 “Keypad Zones” )
NOTE: Only one keypad may be assigned to a zone.
Default
00
I________I_______I Keypad (slot 1) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 2) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 3) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 4) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 5) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 6) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 7) Zone Valid entries are zones 01-32
00
I________I_______I Keypad (slot 8) Zone Valid entries are zones 01-32
[030] Zone Loop Response Options
Default Option ON Off Section
OFF
I________I 1 Zone 1 is Fast Loop Response Zone 1 is Normal Loop Response 5.24
OFF
I________I 2 Zone 2 is Fast Loop Response Zone 2 is Normal Loop Response 5.24
OFF
I________I 3 Zone 3 is Fast Loop Response Zone 3 is Normal Loop Response 5.24
OFF
I________I 4 Zone 4 is Fast Loop Response Zone 4 is Normal Loop Response 5.24
OFF
I________I 5 Zone 5 is Fast Loop Response Zone 5 is Normal Loop Response 5.24
OFF
I________I 6 Zone 6 is Fast Loop Response Zone 6 is Normal Loop Response 5.24
OFF
I________I 7-8 For Future Use