12
Power Up
correct; and check voltage at the far
end. Disconnect furthest item on
Keybus and work back measuring
voltage. The panel will provide around
550mA of current for powering
modules and detection devices.
Always keep this in mind when ex-
panding a system. If you need more
power, you should use a PC5204
module. This will provide an extra
1.0Amp of power.
You may be using some additional
modules with the Power832. Always
repower the control panel after adding
them onto the system. You will also
need to enable supervision, [*][8]
[5015][902]. Wait one minute then
enter [903]. The added modules
should now be displayed. Push the
[#] key when you have finished. If a
unit is not displayed in the [903],
check all of the connections for the
unit.