Power Up
Common Start-Up Problems
Loss of Clock – Panel needs to have
time and date set. To do this press
[*][6][Master Code][1], then enter
time/date as: HH:MM/MM/DD/YY.
TLM – Panel has no phone line
connected. To cure this fault, enter
programming [*][8][Engineer Code]
and enter section 015. Turn off option
7.
Zone Fault/Tamper – Incorrect zone
supervision selected. Enter program-
ming [*][8][Engineer Code] and enter
section 013. Select correct options
from 1 and 2.
Common Start-Up Problems