29
[06] Second System Options
1 [F] Key Disable / Enable
ON: [F] Key Disabled. The [F] Key is disabled and will not function when pressed.
•
OFF: [F] Key Enabled. When pressed and held for 2 seconds, a Fire Alarm will be
generated. An [F] Key alarm reporting code, if programmed, will be transmitted to
the monitoring station and the Sounders will sound.
2 [P] Key Disable / Enable
ON: [P] Key Disabled. The [P] Key is disabled and will not function when pressed.
•
OFF: [P] Key Enabled. When pressed and held for 2 seconds, an Alarm will be
generated. A [P] Key alarm reporting code, if programmed, will be transmitted to
the monitoring station and the Sounders will sound if programmed to do so.
3 [A] Key Disable / Enable
ON: [A] Key Disabled. The [A] Key is disabled and will not function when pressed.
•
OFF: [A] Key Enabled. When pressed and held for 2 seconds, an Auxiliary Alarm will be
generated. An [A] Key alarm reporting code, if programmed, will be transmitted to
the monitoring station. The [A] Key alarm is silent; when the [A] Key is pressed, the
Sounders will not sound. When the [A] Key alarm has been reported to the
monitoring station, the Sounders will sound several beeps to acknowledge completion
of the transmission.
4 [P] Key Audible / Silent
ON: [P] Key Audible. When the [P] Key is pressed and held for 2 seconds, the
Sounders will be activated.
•
OFF: [P] Key Silent. When the [P] Key is pressed and held for 2 seconds, the
Sounders will not be activated.
5 [F] Key Alarm Steady / Pulsed
ON: [F] Key Alarm Sounds Steady Beep. When an [F] key alarm is generated, the
Sounders will sound with a loud, steady alarm sound.
•
OFF: [F] Key Alarm Sounds with Pulsed Beep. When an [F] Key Alarm is generated,
the Sounders will sound with a loud, pulsing alarm sound.
6 Bypassing Disable / Enable
ON: Bypassing Disabled. Users will not be able to manually bypass zones.
•
OFF: Bypassing Enabled. Users will be able to manually bypass all zones other than
Fire Zones.
7 Keypad Lockout Enable / Disable
ON: Keypad Lockout Enabled. After four incorrect Access Codes have been entered on
the Keypad, the system will not accept further entries on the Keypad for 45 seconds;
even valid Access Codes will not be accepted.
•
OFF:Keypad Lockout Disabled. The Keypad will not lock out regardless of the number
of incorrect entries made.
8 AC Frequency
ON: AC Frequency at 50Hz. Use for most European installations.
•
OFF: AC Frequency at 60Hz. Use for North American installations.
•
Indicates default setting
Chapter 8: System Programming Sections
SYSTEM
PROGRAMMING
SECTIONS