Vista de pagina 22
34
[301]-[311] Telephone Numbers
The telephone numbers entered here are for use by the system to
send reporting codes to the central monitoring station, a residential
telephone or pager.
All telephone numbers are 32 digits in length. Hexadecimal digits
may be programmed in the telephone number to perform certain
functions.
The default for contents of sections [301]-[303] is D followed
by 31 ‘F’s:
Enter [*][2][*]
Enter [*][3][*]
Enter [*][4][*]
Enter [*][5][*]
Hex B to dial ‘*’
Hex C to dial ‘#’
Hex D for additional dialtone search (required
for PBX telephone systems)
Hex E to insert a 2 second pause in the tele-
phone number
HEX A is not used
HEX F represents the end of the Phone Number (everything
after F is ignored)
Pressing [#] in these sections will exit and save the entire
phone number. If a telephone number is not programmed,
the panel will not attempt to communicate.
This applies to Telephone Numbers 1 and 2.
[301] First Telephone Number
(32 Digits)
FLASH
I_E_I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
[302] Second Telephone Number (32 Digits)
I_E_I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
[303] Third Telephone Number (32 Digits)
I_E_I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
Use the [F] key to terminate phone number programming in
sections [301] - [303].
[310] Phone Number 1/3
Account Code
FLASH
This is the Account Code used by the panel when communicating
via Phone Numbers 1 and 3
Default FFFF I___I___I___I___I Codes are 4 digits in length.
Valid entries are 0000-FFFF.
[311] Phone Number 2 Account Code
This is the Account Code used by the panel when communicating
via Phone Number 2.
Default FFFF I___I___I___I___I Codes are 4 digits in length.
Valid entries are 0000-FFFF.
[320]-[327] Alarm/Restoral Reporting Codes
These reporting codes are used by the communicator to transmit
zone alarms and restorals for zones 01-32. They are sent to the
Alarms and Restorals Call Direction Group programmed in section
[361]
Alarms Alarm Restorals
Zone Section/Entry Section/Entry
01 [320] I_3_I_A_I [324] I_3_I_A_I
02 I_3_I_A_I I_3_I_A_I
03 I_3_I_A_I I_3_I_A_I
04 I_3_I_A_I I_3_I_A_I
05 I_3_I_A_I I_3_I_A_I
06 I_3_I_A_I I_3_I_A_I
07 I_3_I_A_I I_3_I_A_I
08 I_1_I_1_I I_1_I_1_I
09 [321] I_3_I_A_I [325] I_3_I_A_I
10 I_3_I_A_I I_3_I_A_I
11 I_3_I_A_I I_3_I_A_I
12 I_3_I_A_I I_3_I_A_I
13 I_3_I_A_I I_3_I_A_I
14 I_3_I_A_I I_3_I_A_I
15 I_3_I_A_I I_3_I_A_I
16 I_3_I_A_I I_3_I_A_I
17 [322] I_3_I_A_I [326] I_3_I_A_I
18 I_3_I_A_I I_3_I_A_I
19 I_3_I_A_I I_3_I_A_I
20 I_3_I_A_I I_3_I_A_I
21 I_3_I_A_I I_3_I_A_I
22 I_3_I_A_I I_3_I_A_I
23 I_3_I_A_I I_3_I_A_I
24 I_3_I_A_I I_3_I_A_I
25 [323] I_3_I_A_I [327] I_3_I_A_I
26 I_3_I_A_I I_3_I_A_I
27 I_3_I_A_I I_3_I_A_I
28 I_3_I_A_I I_3_I_A_I
29 I_3_I_A_I I_3_I_A_I
30 I_3_I_A_I I_3_I_A_I
31 I_3_I_A_I I_3_I_A_I
32 I_3_I_A_I I_3_I_A_I
19
Account Information Record
Client_____________________________________________
Address___________________________________________
Telephone_________________________________________
Installation Date___________________________________
Zone
Serial Number Location
01
I___I___I___I___I___I___I _____________________
02
I___I___I___I___I___I___I _____________________
03
I___I___I___I___I___I___I _____________________
04
I___I___I___I___I___I___I _____________________
05
I___I___I___I___I___I___I _____________________
06
I___I___I___I___I___I___I _____________________
07
I___I___I___I___I___I___I _____________________
08
I___I___I___I___I___I___I _____________________
09
I___I___I___I___I___I___I _____________________
10
I___I___I___I___I___I___I _____________________
11
I___I___I___I___I___I___I _____________________
12
I___I___I___I___I___I___I _____________________
13
I___I___I___I___I___I___I _____________________
14
I___I___I___I___I___I___I _____________________
15
I___I___I___I___I___I___I _____________________
16
I___I___I___I___I___I___I _____________________
Notes:
Central Station Telephone Number
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I___I
Central Station Account Number
I___I___I___I___I
Installer’s Code
I___I___I___I___I
Zone
Serial Number Location
17
I___I___I___I___I___I___I _____________________
18
I___I___I___I___I___I___I _____________________
19
I___I___I___I___I___I___I _____________________
20
I___I___I___I___I___I___I _____________________
21
I___I___I___I___I___I___I _____________________
22
I___I___I___I___I___I___I _____________________
23
I___I___I___I___I___I___I _____________________
24
I___I___I___I___I___I___I _____________________
25
I___I___I___I___I___I___I _____________________
26
I___I___I___I___I___I___I _____________________
27
I___I___I___I___I___I___I _____________________
28
I___I___I___I___I___I___I _____________________
29
I___I___I___I___I___I___I _____________________
30
I___I___I___I___I___I___I _____________________
31
I___I___I___I___I___I___I _____________________
32
I___I___I___I___I___I___I _____________________
Notes:
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 29 30

Comentarios a estos manuales

Sin comentarios