24
20 24-Hr Freeze - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
21 24-Hr Latching/Tamper - If this zone is violated, the sys-
tem will not arm until [*][8][Installers Code] is entered.
22 Momentary Keyswitch Arm - Momentary violations of
this zone will alternately arm/disarm the system.
Do not use with wireless zones.
23 Maintained Key Switch Arm - When zone is violated,
the system will arm. When zone is secured, the system
will disarm.
NOTE: Do not use with wireless zones.
24 Future Use
25 Interior Delay - When the system is fully armed (i.e.,
Away Armed) this zone will follow exit delay. It will also
follow the entry delay, provided that the delay zone is
tripped first; otherwise it will go into alarm instantly.
When the system is Stay Armed, this zone will be active,
but when it is tripped, it will initiate the entry delay.
26 24-Hr Non-Alarm Zone - This zone does not sound a
bell, nor transmit any alarm condition to the central sta-
tion. Can be used to sound the door chime.
87 Delay 24-Hr Fire (Wireless) - Used only with wireless
smoke detectors.Delayed 24-Hr Fire (Wireless) works the
same way as the standard fire zone, except the alarm
memory and transmission by the communicator is
delayed by 30 seconds. If the alarm is acknowledged by
pressing any key within 30 seconds, the bells will silence
and the transmission will be aborted. After the alarm has
been acknowledged, and the smoke detector has not
been restored to normal, after 90 seconds the bell output
will be activated again; the user then has another 30 sec-
ond delay before the bell output latches and communica-
tions is activated. A code would then be required to
silence the bell output.
The Fire Delay will be terminated if a 2nd fire zone is
tripped or if the [F] key is pressed during a delay.
88 Standard 24-Hr Fire (Wireless) - Used only with wire-
less smoke detectors. On alarm, the bell output will
sound to indicate that the fire loop has been activated. If
enabled, the communicator will immediately transmit the
alarm to the monitoring station.
Do NOT change the default settings for Zone Attributes
on Fire type zones.
[001] - [004] Zone Definitions
FLASH
This section requires 32 two digit entries. Each two digit entry deter-
mines how the zone will operate. See Zone Definitions on the pre-
ceding page and Zone Attributes section [101]-[132].
Section Zone Default Zone Definition
[001] 01 01
I___I___I
02 03 I___I___I
03 03
I___I___I
04 03 I___I___I
05 04
I___I___I
06 04 I___I___I
07 04
I___I___I
08 88 I___I___I
[002] 09 00
I___I___I
10 00 I___I___I
11 00
I___I___I
12 00 I___I___I
13 00
I___I___I
14 00 I___I___I
15 00
I___I___I
16 00 I___I___I
[003] 17 00
I___I___I
18 00 I___I___I
19 00
I___I___I
20 00 I___I___I
21 00
I___I___I
22 00 I___I___I
23 00
I___I___I
24 00 I___I___I
[004] 25 00
I___I___I
26 00 I___I___I
27 00
I___I___I
28 00 I___I___I
29 00
I___I___I
30 00 I___I___I
31 00
I___I___I
32 00 I___I___I
29
When a valid [P] key alarm is generated, the keypad buzzer
and the bell output will remain silent, but the alarm will still
be transmitted (if programmed).
3 ON Quick Exit Enabled
!
When armed, users may enter the [*][0] command to allow a
single Delay 1 or Delay 2 zone to be activated so they may
leave the premises. Only one Delay zone may be activated;
any additional activity on another Delay zone will cause its
respective alarm sequence. If the Delay zone is still open two
minutes after the [*][0] command is entered, the Entry Delay
will begin. If armed in the Stay mode, the automatic bypass
on Stay/Away zones will not be removed.
OFF Quick Exit Disabled
4 ON Quick Arming Enabled/Function Keys Do
Not Require Code
!
[*][0] arming and Stay/Away function keys may be used to
arm the system without the entry of a valid access code.
OFF Quick Arming Disabled/Function Keys
Require Code
[*][0] arming is not permitted. All Arming keys require an
access code.
5 ON Code Required for Bypassing
After entering the [*][1] Bypass Zones Command, an access
code must be entered before zones may be bypassed.
OFF No Code Required for Bypassing
!
Enter the [*][1] Bypass Zones Command to bypass zones.
6 ON Master Code Not Changeable
The Master Code (Access Code 40) may not be changed by
the user, and may only be programmed in the Installer’s Pro-
gramming mode.
OFF Master Code Changeable
!
The Master Code (#40) may be programmed by the user
using the [*][5][Master Code] command. The Master Code
may also be programmed in section [007]
.
7 ON Telephone Line Monitor (TLM) Enabled
!
The TLM function will be active and the system will indicate a
Trouble #3 condition when using the [*][2] View Trouble
Conditions Command.
OFF Telephone Line Monitor (TLM) Disabled
The TLM function will be shut off and telephone line troubles
will not be indicated by the system.
8 ON TLM Audible when Armed
!
When the system is disarmed, a telephone line monitor trou-
ble will generate a trouble indication as described above. If
the system is armed, a telephone line monitor trouble will
generate an audible alarm on the bell or siren for the dura-
tion of bell timeout or until an access code is entered.
OFF TLM Trouble Only when Armed
A telephone line trouble will generate a trouble indication,
the Trouble LED will come ON, and the keypad sounder will
beep until a key is pressed.
[016] Fourth System Option Codes
1 ON AC Trouble Displayed
!
If AC power fails, the condition will be reported to the moni-
toring station and will be indicated as a Trouble condition on
the system keypad.
OFF AC Trouble NOT Displayed
If AC power fails, the condition will be reported, but the Trou-
ble LED will not light on the system keypad. If [*][2] is
entered to view the system troubles, Trouble #2 will still be
displayed.
2 ON Trouble Light Flashes if AC Fails
!
Whenever AC power is lost from the system, the Trouble LED
will flash in the Ready and Armed modes within 30 seconds
after power is lost. When AC restores, the Trouble LED will
stop flashing within 30 seconds. If enabled, this option will
override the AC display option.
OFF Trouble Light does not follow AC Status
3 ON Blank Keypad when not used
If no keys are pressed for 30 seconds, all keypad lights turn
OFF and the display will blank until the next keypress, Entry
Delay, audible alarm or keypad buzzer condition.
OFF Keypad always Active
!
The keypad lights will remain ON at all times.
4 ON Code Req’d to Remove Keypad Blanking
Before a blanked keypad can be used, a valid access code
must be entered.
OFF No Code Required
!
Pressing any key on a blanked keypad will remove the
blanking.
5 Future Use
6 ON Power Save Mode Enabled
If AC power fails, all keypad lights will be shut OFF. The key-
pad lights will come back ON after a keypress, Entry Delay,
audible alarm or keypad buzzer condition except Door
Chime). The keypad lights will return to the off state after 30
seconds of keypad inactivity.
OFF Power Save Mode Disabled
!
7 ON Bypass Status displayed While Armed
The Bypass status light will be ON if there are zones bypassed
when the system is armed.
OFF Bypass Status NOT displayed While Armed
!
The Bypass light will be ON only while the system is disarmed
to indicate that there are bypassed zones on the system.
When the system is armed, the Bypass light will be OFF.
8 Future Use