22
11 [*][5] User Programming - Console Only - Pressing this key
is the equivalent of entering [*][5]. A Supervisor or Master
access code is required to enter the User Programming menu.
This key only works while the system is disarmed.
12 [*][6] User Functions - Console Only - Pressing this key is
the equivalent of entering [*][6]. A Supervisor or Master
access code is required to enter the User Functions menu.
This key only works while the system is disarmed.
13 [*][7][1] Command Output #1 - Pressing this key is the
equivalent of entering [*][7][1]. An access code may be
required before the output is activated, depending on
attribute 5 of the output. This key works when armed or dis-
armed.
14 [*][7][2] Command Output #2 - Pressing this key is the
equivalent of entering [*][7][2]. An access code may be
required before the output is activated, depending on
attribute 5 of the output. This key works when armed or dis-
armed.
15 Future Use
16 [*][0] Quick Exit - Pressing this key will perform the Quick
Exit function (if enabled). It is the equivalent of pressing [*][0]
while armed. This key only works while the system is
armed.This feature is enabled in section [015], option 3.
17 [*][1] Activate Stay/Away Zones - Pressing this key will
remove the automatic bypass on all Stay/Away zones on the
system. It is the equivalent of pressing [*][1] while armed.
This key only works while the system is armed.
18 Future Use
19 [*][7][3] Command Output #3 - Pressing this key is the
equivalent of entering [*][7][3]. An access code may be
required before the output is activated, depending on
attribute 5 of the output. This key works when armed or dis-
armed.
20 Future Use
21 [*][7][4] Command Output #4 - Pressing this key is the
equivalent of entering [*][7][4]. An access code may be
required before the output is activated, depending on
attribute 5 of the output. This key works when armed or dis-
armed.
27 Disarm (OFF) - Wireless Only
28 Fire Alarm - Wireless Only - See section [000] option [07]
29 Auxiliary Alarm - Wireless Only - See section [000] option
[07]
30 Panic Alarm - Wireless Only - See section [000] option [07]
[000][1-5] Function Key Assignment (Console)
Key Default Option
[1] 01 03 I___I___I
[2] 02 04 I___I___I
[3] 03 06 I___I___I
[4] 04 17 I___I___I
[5] 05 16 I___I___I
[000][6] Keypad Programming
1 ON Local Clock Display Enabled !
System time will be displayed on the keypad
☞
The time is not displayed during [*] programming.
OFF Local Clock Display Disabled
2 ON Local Clock Displays AM/PM !
OFF Local Clock Displays 24 Hour Time
☞
Option 1 must be enabled (ON) for these options.
3 ON Open Zones Override Clock Display !
If a zone goes ‘Open’ on the system the keypad will start
scrolling the open zone(s) without the user pressing a key.
OFF Open Zones Do Not Override Display
Open zones will not scroll until a key is pressed.
4 Future Use
5 ON Alarms NOT Displayed While Armed
When the system is armed there will be no indication of
zones being in alarm. The Alarm icon will not turn on
and the zones in alarm will not scroll.
OFF Alarms Displayed While Armed !
When the system is armed there will be a visual indication
of zones in alarm. The Alarm icon will turn on and the
zones in alarm will scroll.
6 ON Door Chime Enabled for Zone Openings !
If door chime is enabled and a chime zone goes open the
chime will sound.
OFF Door Chime Disabled for Zone Openings
If door chime is enabled and a chime zone goes open the
chime will NOT sound.
☞
Door chime is enabled/disabled with [*][4]
7 ON Door Chime Enabled for Zone Closings !
If door chime is enabled and a chime zone is restored the
chime will sound.
OFF Door Chime Disabled for Door Closings
If door chime is enabled and a chime zone is restored the
chime will NOT sound.
☞
Door chime is enabled/disabled with [*][4]
8 Future Use
31
[030] Hardwired Zone Assignments
This two digit entry indicates which zones will be hardwired zones.
The first entry is for zone 1, the second entry is for zone 2.
Default 00 I___I___I Valid entries are zones 01-32
00 disables the zone
00 I___I___I
[031] Hardwired Zone Loop Response Time
This three digit entry determines how fast the zone will respond to
changes in state. The first entry is for zone 1, the second entry is for
zone 2. Do NOT enter ‘000’. Default is 500 ms.
Default 072 I___I___I___I Valid entries (001-255)
Time = Entry x 7 ms.
072 I___I___I___I
[101]-[132] Zone Attributes
Each zone operates according to the zone definition selected for it
in section [001] - [004] or assigned to it during Flash Programming.
The following table lists the default attributes for each zone type.
This section allows the installer to customize the zone attributes for
specific zones.
1 Audible/Silent - Activates/deactivates alarm output.
2 Steady/Pulsed - Determines if alarm output is steady or pulses
1 second ON, 1 second OFF
3 Activate Chime - Enables zone to activate the chime feature.
4 Bypass Enable - Enables zone to be manually bypassed.
5 Force Arm Enable - Determines if the system can be armed
with the zone violated. At the end of Exit Delay, if this type of
zone is violated, it will be ignored by the system. When the zone
is secured it will be added back into the system. This zone is typ-
ically used for garage doors.
☞
24-Hr Zones must not have Force Arm enabled.
6 Swinger Shutdown Enable - Determines if the system will
shutdown the communicator for the zone after the swinger
limit is reached.
7 TX Delay Enable - Determines if the system will delay commu-
nicating the alarm reporting code to the central station.
8 Wireless Zone - Allows the system to generate low battery
trouble and zone supervisories.
☞
This must be enabled for enrolled wireless devices
[101] -[132] Zone Attributes
Zone Attribute Defaults:
!
= Option ON
%
= Option OFF
Audible Silent
Steady Pulsed
Chime
Bypass
Force Arm
Swing
Tx Delay
Wireless Zn.
Zone Type 12345678
00 Null Zone
% % % % % % % !
01 Delay 1
!!!!!!%!
02 Delay 2
! ! ! ! ! ! % !
03 Instant
!!!!%!%!
04 Interior
! ! % ! % ! % !
05 Int. Stay/Away
!!%!!!%!
06 Dly Stay/Away
! ! % ! ! ! % !
10 24-Hr Supv. Buzzer
%!%!%!%!
11 24-Hr Burglary
! ! % ! % ! % !
12 24-Hr Holdup
%!%%%!%!
13 24-Hr Gas
! % % % % ! % !
14 24-Hr Heating
!%%%%!%!
15 24-Hr Medical
! ! % % % ! % !
16 24-Hr Panic
!!%%%!%!
17 24-Hr Emergency
! ! % % % ! % !
18 24-Hr Sprinkler
!!%%%!%!
19 24-Hr Water
! ! % % % ! % !
20 24-Hr Freeze
!!%%%!%!
21 24-Hr Latching Tamper
! ! % % % ! % !
22 Momentary Keyswitch
%%%%!%%%
23 Maintained KeySwitch
% % % % ! % % %
25 Interior Delay
!!%!%!%!
26 24-Hr Non-Alarm
% % % % ! % % !
87 Dly 24-Hr Fire
!%%%%%%!
88 Stand. 24-Hr Fire
! % % % % % % !