6
[011] PGM11 to PGM14 Output Programming (PC5204)
NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
01
I_______I_______I PGM 11 01 I_______I_______I PGM 13
01
I_______I_______I PGM 12 01 I_______I_______I PGM 14
Other System Options
[012] Keypad Lockout Options
NOTE:If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000 I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
Default Option ON OFF
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors
ON*
I________I 3 Panel shows all troubles when armed Panel shows only Fire troubles when armed
OFF
I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open
ON
I________I 2 Auto-Arm Schedule in [*][6]† Auto-Arm Schedule in Installer Programming Only
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled
ON I________I 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown
OFF
I________I 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
†This option applies to all partitions.
[014] Second System Option Code
Default Option ON OFF
OFF
I________I 1 Arm / Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled
OFF
I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm
OFF I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay
OFF
I________I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay
OFF
I________I 5 Bell Squawk On Trouble No Bell Squawk On Trouble
ON I________I 6 Audible Exit with Urgency Silent Exit Delay
OFF
I________I 7 Exit Delay Termination Enabled Exit Delay Termination Disabled
OFF
I________I 8 Residential Fire Bell is Continuous Residential Fire Bell Follows Bell Cut-off
[015] Third System Option Code
Default Option ON OFF
ON
I________I 1 Fire Keys Enabled Fire Keys Disabled
OFF I________I 2 Panic Keys Audible (Bell / Beeps) Panic Keys Silent
OFF
I________I 3 Quick Exit Enabled Quick Exit Disabled
ON*
I________I 4 Quick Arming Enabled/ Quick Arming Disabled/
Function keys do not require code Function keys require code
OFF** I________I 5 Code Required For Bypassing No Code Required
OFF
I________I 6 Master Code Not Changeable Master Code Changeable
ON
I________I 7 TLM Enabled TLM Disabled
OFF I________I 8 TLM Audible (Bell) When Armed TLM Trouble Beeps When Armed
* When using a PC5132 version 2.1 or older with the WLS909 Wireless Key, Option [4] must be ON for the Arm button to work.
**If option [5] is ON, function keys programmed as [08] Bypass will require an access code when used, even if option [4] is also on.
Comentarios a estos manuales