
21
Section 8: Programmable Output
Programming
Programmable Output Attributes
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009],
[010] & [011].
PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
Section PGM Output 1 2 3 4 5 6 7 8
#Type*
Main Board
[501] 1 ( )
I________I I________| I________| I________| I________| I________| I________| I________I
[502] 2 ( ) I________I I________| I________| I________| I________| I________| I________| I________I
Main Board / PC5208
[503] ** 3 ( )
I________I I________| I________| I________| I________| I________| I________| I________I
[504] ** 4 ( ) I________I I________| I________| I________| I________| I________| I________| I________I
*Record here based on programming in [009], [010] and [011].
** These two sections allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on the
PC5208. If you use both the main panel and the PC5208 outputs, PGM3 will work the same as the first PC5208 output, and PGM4
will work the same as the second PC5208 output.
Attribute: 1 2 3 4 5 6 7 8
ON
Not used Not used True Output Follows Timer Code Req. Not used Not used Not used
OFF
——Inverted On / Off No Code Req. ———
PGM Option
[01] Burg. / Fire Bell Y
[02] Future Use
[03] Sensor Reset Y N
[04] 2-Wire Smoke Support (PGM2 only) Y
[05] Armed Status Y
[06] Ready To Arm Y
[07] Kypd Bzz Follow Y
[08] Courtesy Pulse Y
[09] System Trouble Output / Trouble Options) Y Y Y Y Y Y Y Y
[10] System Event / Event Options) Y Y Y Y Y Y Y Y
[11] System Tamper Y
[12] TLM and Alarm Y
[13] Kiss-off Y
[14] Gnd Strt Pulse Y
[15] Remote Op. Y
[16] LINKS1000 Sup. Y
[17] Away Armed Status Y
[18] Stay Armed Status Y
[19] Comm. Output #1, [*][7][1] Y Y Y
[20] Comm. Output #2, [*][7][2] Y Y N
[21] Comm. Output #3, [*][7][3] Y Y N
[22] Comm. Output #4, [*][7][4] Y Y N
[23] Silent 24 Hr (PGM2 only) Y
[24] Audible 24 Hr (PGM2 only) Y
[25] Delayed Burglary & Fire Bell Y
Attribute:
123456 7 8
PGM Option
ON Serv. req. AC Fail TLM Fault FTC Zone Fault Zone Tmp. Zn. Low Bat. Loss of Clock
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
[09] System Trouble YYYYYY Y Y
ON Burg. Evnt. Fire Evnt. Panic Evnt. Med. Evnt. Supv. Evnt. Priority Evnt. Holdup Evnt. Follows Timer*
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Latched
[10] System Event YYYYYYY N
*If attribute [8] is turned ON, attributes [1-7] must also be turned ON.
Comentarios a estos manuales