K E Y P A D C O M M A N D S
17
Special Note: [✱] [7] [2] – Command Output Option #2:
Press [✱]
[7] [2] [Access Code, if required] to activate all outputs programmed as
one of
PGM output options [03],
[04] or [20].
Traditionally, [✱] [7] [2] has been reserved for resetting smoke detectors. Smoke detectors should now be
programmed as output [03] “Sensor Reset” or [04] “2-Wire Smoke”. Do not program output options [03], [04]
and [20] on the same system.
Sensor reset can also be performed by pressing and holding the Reset function key for two seconds.
Please see Section 5.10 “PGM Output Options” for more information.
[✱]+[8] Installer Programming
Enter [✱][8] followed by the Installer Code to enter Installer Programming
(See Section 4.0 “How to Program”).
[✱]+[9] Arming Without Entry Delay
When a Partition is armed with the [✱][9] command the panel will remove the entry delay from the partition. After
the exit delay, Delay 1 and Delay 2 type zones will be instant and Stay/Away zones will remain bypassed.
(See
Section 5.1 “Zone Definitions”).
A valid access code must be entered after pressing [✱] [9].
[✱]+[0] Quick Arm /Quick Exit
Quick Arm
If the Quick Arm Enable option is enabled the panel can be armed by entering [✱][0]. This is a useful method of
arming a Partition when someone without a User Code will be required to arm a Partition.
The Quick Arm feature must be enabled in order for the Stay/Away function keys to operate as
intended. If the feature is not enabled, the user will be required to enter their access code after
pressing the Stay or Away function key in order to arm the system in the stay or away mode.
Quick Exit
Quick Exit will allow someone to leave an armed premise through a Delay type zone without having to disarm
and rearm the system.
When [✱][0] is entered, if the Quick Exit Enabled option is enabled, the panel will provide a two minute window
to exit. During this time the panel will ignore the first activation of a Delay type zone. When the Delay zone is
secured the panel will end the two minute time period.
If a second Delay zone is tripped, or if the zone is not restored after two minutes, the panel will start entry delay.
The Quick Exit feature should not be used on Global Delay zones.
If Quick Exit is used on a partitioned system, Keypad Blanking and Access Code Required to Remove
Blanking should be enabled.
Code Required for Bypass .................................... Section [015], Option [5]
Master Code Not Changeable option ................... Section [015], Option [6]
Quick Arm Enable .................................................. Section [015], Option [4]
Quick Exit Enable ................................................... Section [015], Option [3]
3.5 Function Keys
There are 5 function keys on the PC5010 keypads labelled Stay, Away, Chime, Reset and
Exit. The operation of these keys is described below. The function is activated by
pressing and holding the key for 2 seconds.
“Stay” - Stay Arm
Arms the partition to which the keypad is assigned. All Stay/Away type zones will be
automatically bypassed. Delay type zones will provide entry and exit delay. The Quick Arm
feature must be enabled for this key to function
(Section [015], Option [4])
. If Quick
Arming is not enabled, the user must enter their access code after pressing the
function key in order to arm the system in the Stay mode.
“Away” - Away Arm
Arms the partition to which the keypad is assigned. All Stay/Away type zones will be active at the end of the exit
delay. Delay type zones will provide entry and exit delay. The Quick Arm feature must be enabled for this key to
function
(Section [015], option [4])
. If Quick Arming is not enabled, the user must enter their access code after
pressing the function key in order to arm the system in the Away mode.
“Chime” - Door Chime On/Off
Pressing the key will toggle the Door Chime feature ON or OFF. One solid beep means the feature has been
disabled, three short beeps means it has been enabled.
“Reset” - Reset Smoke Detectors
Pressing this key will cause the panel to activate for 5 seconds any output programmed as Sensor Reset. In addition two
wire smoke detectors connected to PGM2 will also be reset
(See Section 3.4 “[
✱
] Commands, [
✱
][7][2]”).
“Exit” - Activate Quick Exit
Pressing this key will cause the panel to activate the Quick Exit feature
(See Section 3.4 “[
✱
] Commands, [
✱
][0]”).