DSC PC 1555 Manual de instalación Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
29
[301] - First Telephone Number
[302] - Second Telephone Number
[303] - Third Telephone Number
NOTE:
There is a static delay of 2 seconds before any addi-
tional dial tone search in a phone number.
NOTE:
The panel will not attempt to communicate, if no
phone number is programmed. This applies to phone num-
bers 1, 2 and 3.
[304] - Call Waiting Cancel Dialing String
This is a 6-digit Hex entry that is used to disable Call
Waiting on a Call Waiting-equipped phone line. This is
typically *70 in most areas. Dialing this string before a
phone number will disable Call Waiting for the duration
of the call. If this section is programmed (not FF), and Sec-
tion 382, Option 4 is ON, the panel will dial this string in
place of the first digit of the phone number (Sections
[301]-[303]). This only applies to the first attempt that is
made to each phone number.
NOTE:
If not all 6 digits are required they should be filled
with Hex F.
All 6 digits of this section need to be programmed in
order for any changes to be accepted.
Communicator - Account Codes
The System Account Code will be used by the panel
when communicating System events (e.g. Low Battery,
Test Transmission). This account code can be up to six
digits in length for the SIA Communications format. Only
the SIA reporting format supports six-digit account
codes. All other formats will use the first four digits of the
account code.
NOTE:
If the communicator is programmed for the SIA
reporting format, the system will use this account code for
all partitions.
There is 1 Partition Identifier Codes
Partition Identifier Codes Partition Identifier Codes
Partition Identifier Codes (or account codes)
programmable, for the system. The account code is used
by central station to determine which panel is calling.
The panel will report using partition 1 account code.
[310] - System Account Code
This is the account code used by the panel when communi-
cating System events (e.g., Low Battery, Test Transmission).
This account code can be up to six digits in length for the
SIA Communications format.
Only SIA supports 6-digit account codes. If the last two
digits of the account code are FF, the panel will only use
the first four digits. All other formats will use the first
four digits of the account code.
The call directions that use this account code are System
Maintenance (Troubles, Zone Faults, etc.) and System Test
Transmissions.
NOTE:
SIA will use this account code for Partition 1 and sys-
tem events. System events will be identified by Nri0, with
partition 1 using Nri1.
[311] - Partition 1 Account Code
These account codes are used by the panel when commu-
nicating events for partition 1 when using formats other
than SIA.
NOTE:
The system account codes is 4 digits in length. Valid
entries are 0000-FFFE.
[320] - [358] Reporting Codes
Communicator - Reporting Codes
Unless you are using Automatic Contact ID or Automatic
SIA formats, reporting codes must be programmed in
order for the panel to report events to the central station.
Reporting codes are two digits and can use hexadecimal
digits A through F. To disable a reporting code, program it
as FF (default setting) or 00. For a complete description of
reporting codes which can be programmed and lists of
Automatic Contact ID and SIA format codes, see section
Appendix A: ‘Reporting Codes‘.
[320]-[321] - Alarm Reporting Codes, Zones 1-32
The panel will transmit the Zone Alarm reporting code
for a zone when the zone goes into alarm. 24-hr type
zones will go into alarm whether the panel is armed or
disarmed and report to the central station. All other zone
types will only go into alarm if the panel is armed.
Reporting codes can be one or two digits and can use Hex
digits (A through F). The following is a description of the
different reporting codes that can be programmed and
when the events will be reported to the central station.
[324]-[325] - Alarm Restoral Reporting Codes,
Zones 1-32
If the Restoral on Bell Time-out
Restoral on Bell Time-outRestoral on Bell Time-out
Restoral on Bell Time-out option is selected the
panel will send the Zone Restoral
Zone RestoralZone Restoral
Zone Restoral Reporting Code for the
zone when the alarm output times out AND the zone is
secure. If the zone is not secured when the alarm output
times out the panel will send the restoral immediately
after the zone is secured.
If the Restoral on Bell Time-out
Restoral on Bell Time-outRestoral on Bell Time-out
Restoral on Bell Time-out option is not selected the
panel will immediately send the Zone Restoral reporting
code when the zone is secured or when the panel is dis-
armed, regardless if the alarm output is active or not.
NOTE:
24-hr type zones will report the restoral immedi-
ately after the zone is secured.
[328] - Miscellaneous Alarm Reporting Codes
Duress Alarm:
this reporting code will be transmitted to
the monitoring station whenever a Duress code is used to
perform any function on the system.
Opening After Alarm:
this reporting code will be trans-
mitted to the monitoring station on opening if an alarm
has occurred during the previous armed period.
Recent Closing
: a Recent Closing transmission will be sent
if an alarm occurs within 2 minutes of an exit time expira-
tion. The Recent Closing report will be sent for the first
alarm only.
Zone Expander Supervisory Alarm:
this reporting code is
sent when the system loses communications with any
zone expander module (PC5132 or keypad with on-board
zone).
Zone Expander Supervisory Restoral
: this reporting code
is sent when the system regains communications with all
zone expander modules (PC5132 or keypad with on-
board zone) that have been enrolled on the system.
Cross Zone / Police Code Alarm:
When using Cross Zon-
ing (Section 018, Option 6 ON), this reporting code will be
sent when two Crossed Zones go into alarm during the
cross zone period.
When using Police Code (Section 018, Option 6 OFF), this
reporting code will be sent when any two zones go into
alarm.
If the
Double Hit
option has been enabled, this reporting
code will be sent when two zone alarms occur on the
same zone and the Burglary Verified timer has not
expired.
NOTE:
Only one reporting code will be sent during each
armed to armed period when using Police Code.
Burglary Not Verified
: this reporting code will be sent
after the Burglary Verified Timer expires after a zone
alarm occurs.
Vista de pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 55 56

Comentarios a estos manuales

Sin comentarios