31
Output #1 on the PC5200/PC5204 Power Supply/Out-
put Module.
General System Supervisory Trouble:
a General System
General SystemGeneral System
General System
Supervisory Trouble
Supervisory TroubleSupervisory Trouble
Supervisory Trouble reporting code will be transmitted if
any module goes missing from the Keybus. If the module
is a zone expander the panel will also transmit the
Zone
Expander Supervisory Alarm Trouble
reporting code.
[346] - Maintenance Restoral Reporting Codes
Battery Trouble Restoral
Battery Trouble RestoralBattery Trouble Restoral
Battery Trouble Restoral: the Battery Trouble Restora
Battery Trouble RestoraBattery Trouble Restora
Battery Trouble Restoral
reporting code will not be transmitted until the battery
has been charged over 12.5 V
DC
.
AC Failure Trouble Restoral
AC Failure Trouble RestoralAC Failure Trouble Restoral
AC Failure Trouble Restoral: the AC Failure Trouble
AC Failure TroubleAC Failure Trouble
AC Failure Trouble
Restoral
RestoralRestoral
Restoral
reporting code will be transmitted once AC
power has been restored for the amount of time pro-
grammed for AC Failure Communication delays.
Bell Circuit Trouble Restoral
Bell Circuit Trouble RestoralBell Circuit Trouble Restoral
Bell Circuit Trouble Restoral: the Bell Circuit Trouble
Bell Circuit TroubleBell Circuit Trouble
Bell Circuit Trouble
Restoral
RestoralRestoral
Restoral reporting code will be transmitted as soon as the
open condition on the bell output is corrected.
Fire Trouble Restoral
Fire Trouble RestoralFire Trouble Restoral
Fire Trouble Restoral: the Fire Trouble Restoral
Fire Trouble RestoralFire Trouble Restoral
Fire Trouble Restoral reporting
code will be transmitted when the correct resistance value
is measured on any Fire type zone.
Auxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble RestoralAuxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble Restoral: the panel con-
stantly checks the AUX output, when the excessive cur-
rent draw is removed the panel will reset the output and
transmit an Auxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble RestoralAuxiliary Power Supply Trouble Restoral
Auxiliary Power Supply Trouble Restoral
reporting code.
TLM Restoral:
TLM Restoral:TLM Restoral:
TLM Restoral: the TLM Restoral reporting code will be
transmitted immediately after the Trouble is restored.
General System Trouble Restoral
General System Trouble RestoralGeneral System Trouble Restoral
General System Trouble Restoral: a General System Trou-
ble Restoral
reporting code will be transmitted when the
panel detects none of the following:
AC Power Failure Low Battery
AUX Output Trouble Output #1 on the PC5200 /
PC5204 power Supply/Output Module after a Trouble
was reported.
General System Supervisory Restoral
General System Supervisory RestoralGeneral System Supervisory Restoral
General System Supervisory Restoral: the General System
Trouble Restoral reporting code will be transmitted when
the control panel detects all modules enrolled on the key-
bus
[347] - Miscellaneous Maintenance Reporting Codes
Telephone Number 1 (2) FTC Restore:
Telephone Number 1 (2) FTC Restore:Telephone Number 1 (2) FTC Restore:
Telephone Number 1 (2) FTC Restore: if the panel fails to
transmit information to the central station it will display a
failure to communicate Trouble condition. The panel will
transmit a Phone Number 1 Failure
Phone Number 1 FailurePhone Number 1 Failure
Phone Number 1 Failure to Communicate
reporting code or a
Phone Number 2 Failure to Communi-
cate
reporting code the next time it calls the central sta-
tion. The panel will transmit the old events, followed by
the failure to communicate, followed by the new events.
Event Buffer 75% Full:
Event Buffer 75% Full:Event Buffer 75% Full:
Event Buffer 75% Full: If the event buffer is uploaded on a
regular basis an Event Buffer 75% Full
Event Buffer 75% FullEvent Buffer 75% Full
Event Buffer 75% Full reporting code can
be transmitted to warn that the Buffer is almost full.
DLS Lead In:
DLS Lead In:DLS Lead In:
DLS Lead In: The DLS Lead In
DLS Lead InDLS Lead In
DLS Lead In reporting code will only
be transmitted if the DLS Call Back feature is being used
(see Section 5.8 "Downloading"). Before the panel calls the
computer back it will call the central station and transmit
the reporting code to indicate a download session is
about to begin.
DLS Lead Out:
DLS Lead Out:DLS Lead Out:
DLS Lead Out: After a downloading session is attempted
and/or completed, the panel will transmit a DLS Lead
DLS LeadDLS Lead
DLS Lead
Out
OutOut
Out reporting code.
Zone Fault Alarm:
Zone Fault Alarm:Zone Fault Alarm:
Zone Fault Alarm: The Zone Fault Alarm
Zone Fault AlarmZone Fault Alarm
Zone Fault Alarm reporting code
will be transmitted when there is a short detected on any
DEOL zone and/or a loss of Supervisory on a wireless
zone.
Zone Fault Restoral:
Zone Fault Restoral:Zone Fault Restoral:
Zone Fault Restoral: The Zone Fault Restoral
Zone Fault RestoralZone Fault Restoral
Zone Fault Restoral reporting
code will be transmitted when the fault condition on the
zone is corrected.
Delinquency Code:
Delinquency Code:Delinquency Code:
Delinquency Code: The Delinquency
DelinquencyDelinquency
Delinquency reporting code is
sent whenever the panel is not armed within the number
of days programmed for the Delinquency Transmission
Delay.
General Zone Low Battery Alarm:
General Zone Low Battery Alarm:General Zone Low Battery Alarm:
General Zone Low Battery Alarm: the panel will transmit
a General Zone Low Battery Alarm
General Zone Low Battery AlarmGeneral Zone Low Battery Alarm
General Zone Low Battery Alarm reporting code when
a wireless detector indicates a low battery condition and
the delay programmed in Zone Low Battery Transmission
Delay expires.
General Zone Low Battery Restoral:
General Zone Low Battery Restoral:General Zone Low Battery Restoral:
General Zone Low Battery Restoral: the General Zone
Low Battery Restoral reporting code will be transmitted
when the low battery condition on all wireless zones is
corrected. The specific zone that caused the trouble will
be stored to the event buffer.
Installer Lead In:
Installer Lead In:Installer Lead In:
Installer Lead In: a reporting code will be sent to the cen-
tral monitoring station when Installer Programming is
entered through the keypad.
Installer Lead Out:
Installer Lead Out: Installer Lead Out:
Installer Lead Out: a reporting code will be sent to the
central monitoring station when Installers programming
is exited.
[348] - Test Transmission Reporting Codes
Walk Test End:
the Walk Test End
Walk Test EndWalk Test End
Walk Test End reporting code will be
transmitted when a Walk Test is terminated.
Walk Test Begin:
the Walk Test Begin
Walk Tes t B e g i n Walk Test Begin
Walk Test Begin reporting code will
be transmitted when a Walk Test is initiated.
Periodic Test Transmission with Trouble
Periodic Test Transmission with TroublePeriodic Test Transmission with Trouble
Periodic Test Transmission with Trouble - the panel can be
programmed to transmit a Periodic Test Transmission
Periodic Test TransmissionPeriodic Test Transmission
Periodic Test Transmission
with Trouble reporting code in place of the standard Peri-
odic Test Transmission if any of the following conditions
exist.
Fire Zone Trouble (Zones 1-32)
Battery Trouble (PC1555 CP-01, PC520X)
Fire Zone Alarm (Zones 1-32, Two-Wire Smoke
Aux Trouble (PC1555 CP-01)
Fire Trouble (2-wire Smoke)
Bell Trouble (PC1555 CP-01)
Fire Tamper/Low Sensitivity (Wireless)
•Module Supervisory
Fire Zones Bypassed (Zones 1-32)
Fire Supervisory (Wireless)
TLM Trouble (PC1555 CP-01)
AC Trouble (PC1555 CP-01, PC520X)
FTC Trouble
Periodic Test Transmission:
the Periodic Test Transmission
reporting code will be transmitted at the specified time,
(programmed in Section 378) every X number of days (see
Section 377).
System Test:
the System Test reporting code will be trans-
mitted when a system test is performed on the panel.
Links 1000 Test Transmission Code:
the Links1000 Test
Transmission reporting code will be transmitted via the
LINKS1000 cellular transmitter at the programmed inter-
val (see ‘Test Transmission Cycles’ section [377]) and time
of day (see Section [378]) of the LINKS Periodic Test
Transmi ss ion.
NOTE:
To disable this transmission of this reporting code, 00
must be entered.
[350] - Communicator Format Options
Communicator - Reporting Formats
Communicator - Reporting FormatsCommunicator - Reporting Formats
Communicator - Reporting Formats
Each central station telephone number of the panel can be
programmed to report using any one of the 5 formats
available. The following formats are supported: Pulse (10
and 20 bps), Contact ID, SIA, Residential Dial and a Pager
format. The following is a description of each.
Vista de pagina 36