P R O G R A M D E S C R I P T I O N S
33
5.17 Swinger Shutdown
The swinger shutdown feature is designed to prevent a runaway communicator from tying up the central
station. Different limits can be programmed for Zone Alarms, Zone Tampers
and Maintenance
signals.
After the panel has communicated the programmed number of transmissions for an event it will no longer
report that event until the swinger shutdown is reset.
For example, the swinger shutdown limit for Zone Alarms is set to [003]. The panel will not send more than
3 alarm signals for each zone with a swinger attribute until the swinger shutdown is reset.
Swinger Shutdown
will be reset when the panel is armed or every day at midnight. Once reset, the panel
will again communicate normally.
Swinger Shutdown Limit (Alarms) ................. Section [370]
Swinger Shutdown Limit (Tampers) .............. Section [370]
Swinger Shutdown Limit (Maintenance)........ Section [370]
5.18 Transmission Delay
If Transmission Delay is selected for a zone the panel will delay reporting the alarm for the number of
seconds programmed for Transmission Delay Time. If the panel is disarmed before the delay time
expires the panel will not report the alarm to central station. If the panel is not disarmed in time the panel
will communicate normally.
This is a global feature.
Transmission Delay Enable ........................... Sections [101] to [132], Option [7]
Transmission Delay Time ............................... Section [370]
5.19 Keypad Backlighting
The keys of all the keypads can be backlit to provide easy viewing in dim lighting conditions. If the
Keypad Backlighting Option
is enabled the keys will be illuminated.
Keypad Backlighting Option .......................... Section [016], Option [5]
5.20 Arming /Disarming Options
If the Arm/Disarm Bell Squawk option is enabled the panel will squawk the alarm output once upon
arming and twice upon disarming. The Opening After Alarm Keypad Ringback option will give you the
ability to beep the keypad 10 times rapidly if the panel is disarmed after an alarm occurred. The Opening
After Alarm Bell Squawk
option will give you the ability to squawk the bell output 10 times rapidly if the
panel is disarmed after an alarm occurred.
Closing Confirmation, if enabled, will cause the keypad to beep 10 times rapidly after the closing
reporting code has been transmitted to central station.
Arm/Disarm Bell Squawk............................... Section [014], Option [1]
Opening After Alarm Keypad Ringback......... Section [381], Option [1]
Opening After Alarm Bell Ringback............... Section [381], Option [2]
Closing Confirmation ..................................... Section [381], Option [4]
5.21 Automatic Arming
There are two different Auto-Arming methods available. Each Partition can be programmed to Auto-Arm at
a specific time every day if it is in the disarmed condition. Also a Partition can also be programmed to
Auto-Arm if no activity is registered for a programmed number of minutes.
Before the Auto-Arm at a specific time function will work correctly the present Time of Day
must be
programmed.
When the internal panel clock matches the Auto-Arm Time
the panel will check the status of the Partition.
If armed, the panel will do nothing until the next day at the Auto-Arm Time, when it will check again.
If disarmed the panel will sound the buzzer of all keypads assigned to the partition for one minute. If a
valid User Code is entered the Auto-Arm will be aborted. The panel will also transmit an Auto-Arm Abort
Reporting Code