P R O G R A M D E S C R I P T I O N S
36
5.29.2 Factory Default Main Panel (Software) and other Modules
Step 1 - Enter the Installer Programming mode.
Step 2 - Enter Program Section [XXX].
Step 3 - Enter the Installer Code.
Step 4 - Enter Program Section [XXX] again.
The panel will take a few seconds to perform the default. When the keypad is again operational the default is
complete.
Restore Main Panel (Software) to Factory Default Programming ....... Section [999]
Restore Escort5580 to Factory Default Programming ........................ Section [995]
Restore PC5400 to Factory Default Programming ............................. Section [997]
Restore PC5928 to Factory Default Programming ............................. Section [998]
5.30 Installer Lockout
If Installer Lockout is selected a hardware default cannot be performed. If a software default is performed
all programming will restore to factory default.
When Installer Lockout Disable is selected the panel will restore all programming to factory defaults if a
hardware or software default is performed on the main control panel.
To enable or disable Installer Lockout perform the following:
Step 1 - Enter Installer Programming
Step 2 - Enter Program Section [XXX]
Step 3 - Enter the Installer Code.
Step 4 - Enter Program Section [XXX] again.
Installer Lockout Enable ................................ Section [990]
Installer Lockout Disable ............................... Section [991]
5.31 Walk Test (Installer)
The Installer Walk Test can be used to verify that each zone of the panel is working. To perform a Walk
Test, enter the following:
Step 1 - Enter Installer Programming
Step 2 - Enter Section [901]
When any zone is violated the panel will activate the Bell Output for two seconds, log the event to the
Event Buffer and communicate the alarm to central station.
To stop the test, you must do the following:
Step 1 - Enter Installer Programming
Step 2 - Enter Section [901]
5.32 International Programming
5.32.1 [700] Automatic Clock Adjust
In order to compensate for timing inaccuracies, the panel may be programmed to add or subtract
seconds during the last minute of each day. Valid entries are 01 - 99. The default setting is 60 seconds. To
determine the value to be programmed in this section, monitor the amount of time lost or gained by the
panel over a period of time. Then, calculate the average amount of time per day that the panel gains or
loses. If the clock’s timing is off, it may be corrected with this setting.
Example #1: The clock loses an average of 9 seconds per day.
Solution: Program the panel to adjust the clock by 51 seconds (instead of the default 60 seconds) for the
last minute of each day in section [700]. This will speed up the panel’s clock by 9 seconds, thus correcting
the problem.
Example #2: The clock gains an average of 11 seconds per day.
Solution: Program the panel to adjust the clock by 71 seconds (instead of the default 60 seconds) for the
last minute of each day in section [700]. This will slow down the panel’s clock by 11 seconds, thus
correcting the problem.
5.32.2 [701] First International Option Code
1.Power Line Frequency: 50Hz/60Hz
2.Timebase is Internal Crystal: The timebase is the internal crystal oscillator. In cases of unstable AC
power input, the internal crystal can be used to keep the most accurate timbase
Time base is AC line: The timebase is the AC power input. If the 50 or 60Hz AC power input is very
stable it can be used as the timebase.