On an PK5501/LCD5501Z keypad, the display says “Open” when any zone (detector) is activated. To see which zones are
open, press [#]. The keypad will scroll the numbers of all open zones.
On a PK5508/PK5516/PC55XXZ keypad, the zone light turns on when the zone (detector) is activated. The zone light
turns OFF when the zone is closed (e.g., door or window closed).
Note: Some features described above will not be functional unless enabled by your installer. Ask your installer which
features are functional on your system.
Walk Test Mode
The installer can initiate a Walk Test mode for the system. While in Walk Test mode, The Ready, Armed, and Trouble
LED's will flash to indicate that Walk Test is active. When the system automatically terminates the Walk Test modes, it
will annunciate with an audible warning (5 beeps every 10 seconds), beginning five minutes prior to the termination of
the test.
Allowing Computer Access to Your System
From time to time, your installer may need to send information to or retrieve information from your security system.
Your installer will do this by having a computer call your system over the telephone line. You may need to prepare your
system to receive this ‘downloading’ call. Press [*][6][Master code][5] at any keypad. This allows downloading for a
limited period of time. During this time, the system will answer incoming downloading calls.
Other System Information
Language Selection
Your keypad may have the capability to display messages in different languages.
1. Press and hold both [< >] keys simultaneously.
2. Using the [< >] keys, scroll through the available languages.
3. Press [*] to select your desired language.
Time & Date Programming
Press [*][6], plus your Master Access Code or press the time programming function key (programmed by your installer).
Press [1] to select Time and Date.
When using the PK5500/LCD5500, use the [< >] scroll keys to find the menu option and press [*] to select.
Enter the time in 24-hr format (HH:MM), followed by the date (MM:DD:YY). Press [#] to exit programming.
Note: If you have an LCD keypad, your installer may have programmed your system to display the time and date while
the keypad is idle. If this is the case, you can press the [#] key to clear the date and time display.
Alarm Memory
When an alarm occurs, the Memory or System indicator (and Fire indicator, if applicable) will turn on.
To view which sensor(s) generated the alarm, press [*][3]. The Memory or System indicator and corresponding sensor
number will flash (i.e., sensor 3).