Notes on Access Codes and Programming
1. There will still be 37 codes if option selected for 6-digit access codes.
o [*][5][MASTER CODE] [01 to 32, 33, 34, 40, 41, 42] to program access codes
o [*][5][MASTER CODE][8] enters the Partition Assignment Mode [01 to 32, 33, 34, 41, 42] to edit access
code partition assignments
o [*][5][MASTER CODE][9] Enters the Attribute Mode [01 to 32, 33, 34, 41, 42] to edit access code
Attributes
2. The Master Code’s attributes cannot be changed.
3. When a new code is programmed in [*][5] it will be checked against all other codes in the system. If a duplicate
code is found, an error tone is given and the code is returned to what it was before it was changed. This applies
to both 4 and 6-digit codes.
Erasing an Access Code
To erase a code, select the code and enter [*] as the first digit. If [*] is entered, the system will delete the code
immediately and the user will be returned to select another code.
User Function Commands
First disarm the system then enter [*][6][Master Code]. The[*][6] command is used to gain access to the following list of
Master functions of the system.
1. Time and Date - Enter four digits for 24 Hour System Time (HH-MM). Valid entries are 00-23 for the hour and
00-59 for minutes. Enter six digits for the Month, Day and Year (MM-DD-YY).
2. Auto-Arm Control - Pressing [2] while in the User Function menu will enable (three beeps) or disable (one long
beep) the Auto-arm feature, by partition. With this feature enabled, the panel will automatically arm in the
Away mode (Stay Away zones active) at the same time each day. The auto-arm time is programmed with the
[*][6][Master Code][3] command.
3. Auto-Arm Time - The system can be programmed to arm at a programmed time each day, per partition.
Upon entry of this section, enter 4 digits for the 24-hour Auto-arm time for each day of the week.
At the selected auto-arm time, the keypad buzzers will sound for a programmed amount of time (programmable
by the installer only) to warn that an auto-arm is in progress. The bell can also be programmed to squawk once
every 10 seconds during this warning period. When the warning period is complete, the system will arm with no
exit delay and in the Away Mode.
Auto-arming can be cancelled or postponed by entering a valid access code only, during the programmed
warning period. Auto-arming will be attempted at the same time the next day. When the auto-arming process is
cancelled or postponed, the Auto-arm Cancellation Reporting Code will be transmitted (if programmed).
If arming is inhibited by one of the following, the Auto-arm Cancellation transmission will be communicated.
o AC / DC Inhibit Arm
o Latching System Tampers
o Zone Expander Supervisory Fault
4. System Test - The system’s Bell Output (2s), Keypad Lights and Communicator are tested. This test will also
measure the panel’s standby battery.
5. Enable DLS/Allow System Service - If enabled, the installer will be able to access Installer Programming by DLS.
In case of DLS access this provides a window where rings will be detected by the panel. The DLS window will
remain open for six hours, during which time the installer will be able to enter DLS an unlimited number of
times. After the six-hour window has expired, Installer’s Programming will be unavailable again until the window
is re-opened.