22
NOTE: If attribute [8] is turned ON, attributes [1-7] must also
be turned ON.
PGM Output Timer. . . . . . . . . . . . . . . . . . . . . . . Section [164]
[11] System Tamper (All Sources)
The PGM output will activate when any tamper condition is
present and will deactivate when all tampers are restored.
[12] TLM and Alarm
The PGM output activates when the system experiences both
a telephone line trouble and an alarm. When the system is
armed, the output will deactivate only if an access code is
entered or if the telephone line is restored.
If an alarm activates this output in the disarmed state, the out-
put will deactivate if a user enters a valid access code while
the Bell Cut-off timer is counting down, or if the telephone line
is restored. The output will also deactivate if someone arms
the system after the Bell Cut-off has expired.
NOTE: This output will activate for all silent and audible alarms
except the Duress alarm.
[13] Kissoff Output
The output will activate for two seconds after the control panel
receives the kissoff transmission from the central station.
[14] Ground Start Pulse
The PGM Output will activate for two seconds to obtain a dial
tone on Ground Start telephone equipment before the panel
attempts to dial. Insert two 2-second pauses at the beginning
of the telephone number when using this option.
[15] Remote Operation (DLS 2002 Support)
This output can be activated and deactivated remotely using
the DLS software.
[16] LINKS1000 Support (PGM1 Only)
The PGM output will be used as a data wire to communicate
telephone number information for the LINKS1000 cellular unit.
[17] Away Armed Status
When the system is armed in the Away mode, the PGM output
will activate at the beginning of the exit delay. The output
deactivates when the panel is disarmed.
[18] Stay Armed Status
When the system is armed in the Stay mode, the PGM output
will activate at the beginning of the exit delay. The output
deactivates when the panel is disarmed.
[19] [*][7][1] Command Output Option #1
[20] [*][7][2] Command Output Option #2
These outputs are user-initiated by entering [*][7][1-2] at any
keypad. When any output is activated, three acknowledgment
beeps are sounded.
NOTES on Option [20] [*][7][2]:
Press [*][7][2][Access Code, if required] to activate any out-
put programmed as one of PGM output option [03] or [20].
Traditionally, [*][7][2] has been reserved for resetting smoke
detectors. Smoke detectors should now be programmed as
output [03] “Sensor Reset”.
NOTE: Only ONE of options [03] Sensor Reset and [20]
[*][7][2] Command Output Option #2 may be programmed on
the same system.
[21]-[24] For future use
PGM Output Attributes
In addition to programming the output type, you must also
program the PGM output attributes for each output.
PGM output options [09] “System Trouble” and [10] “System
Event” have their own unique set of attributes listed below the
description of each output type.
PGM output options [01], [03], [05]-[08], [11]-[20] have the
following attributes:
Attribute ....ON OFF
[1] .......PGM Enable PGM Disable
[3] .......True Output Inverted Output
Attribute ON: the output energizes when activated
Attribute OFF: the output de-energizes when acti-
vated
[4] .......Output Pulsed Output ON/OFF
Attribute ON: the output will activate once for the
amount of time programmed in section [164]
when initiated by the user
Attribute OFF: the output will toggle ON or OFF
when initiated by the user.
(Only applicable to options [19]-[20].)
[5] .......Access Code Req. No code Req.
Attribute ON: the output requires a code for acti-
vation.
Attribute OFF: no code required.
(only applicable to keypad-activated outputs)
PGM attributes return to their default settings when you
change PGM output options. Please see the programming
worksheets for a list of the default settings for each PGM out-
put type.
Be careful when selecting the normal and active states of
each PGM output to ensure that an undesirable output state
does not occur after a loss and restore of AC power.
NOTE: Attribute [3] must be ON (default) for PGM output
option [16].
NOTE: If you program more than one PGM output as the
same output type (e.g. if PGM1 and PGM2 are both pro-
grammed as [19] Command Output 1), the settings for output
attributes [1], [2] and [5] must be the same. This does not apply
to outputs programmed as types [09] and [10].
PGM Output Attributes . . . . . . . . . . . . . . Section [141]-[142]
5.12 Telephone Line Monitor (TLM)
When the TLM Enable option is selected, the panel will super-
vise the telephone line and will indicate a trouble condition if
the telephone line is disconnected.
If the TLM Enable option is ON, the panel will check the tele-
phone line every 10 seconds. If the telephone line voltage is
below 3V for the number of checks programmed in the TLM
Trouble Delay section, the panel will report a TLM trouble.
The default number of checks is 3. Enter a number from [003]
to [255] in the TLM Trouble Delay section to change the num-
ber of checks before the TLM trouble is reported. Program-
ming a delay means that a momentary interruption of the
telephone line will not cause a trouble condition.
If the TLM Trouble Beeps When Armed option is enabled,
the panel will indicate a TLM trouble at the keypad while the
system is armed. To activate the bell output in the case of a
TLM trouble while the system is armed, the TLM Audible
(Bell) When Armed option must be selected.
When the trouble condition is restored, the panel can send a
TLM Restoral reporting code. Any events which occur while
the telephone line is down will also be communicated.
If the LINKS1000 Cellular Communicator, or LINKS2X50 is
being used, the panel can be programmed to report a TLM
Trouble Reporting Code.
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 55 56

Comentarios a estos manuales

Sin comentarios

AEG Electrolux HM604060MB manuales

Manuales del propietario y guías del usuario para No AEG Electrolux HM604060MB.
Ofrecemos 6 manuales en pdf AEG Electrolux HM604060MB para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para No AEG Electrolux

Modelos Tipo de documento
FAV35080IM Manual de usuario   Aeg-Electrolux FAV35080IM Benutzerhandbuch, 44 paginas
EE4003011M Manual de usuario   Aeg-Electrolux EE4003011M Handleiding [en] , 28 paginas
FM2500DD-A Manual de usuario   Aeg-Electrolux FM2500DD-A Benutzerhandbuch [de] [en] [fr] , 20 paginas
HK634150XB Manual de usuario   Aeg-Electrolux HK634150XB Uživatelský manuál, 16 paginas
B9878-5-M Manual de usuario   Aeg-Electrolux B9878-5-M Food Index [it] , 24 paginas
BE3003000M Manual de usuario   Aeg-Electrolux BE3003000M Manuel utilisateur, 28 paginas
BP9314001M Libro de recetas   Aeg-Electrolux BP9314001M Recipe Book, 56 paginas
47745IQ-WN Manual de usuario   Aeg-Electrolux 47745IQ-WN Ohjekirja, 76 paginas
30006FFW GR R07 Manual de usuario Aeg-Electrolux 30006FFW GR R07 Εγχειρίδιο χρήστη, 52 paginas
E3050-6-M Manual de usuario   Aeg-Electrolux E3050-6-M User Manual, 24 paginas
41056VH-MN Manual de usuario   Aeg-Electrolux 41056VH-MN Používateľská príručka, 32 paginas
HC412010GB Manual de usuario     Aeg-Electrolux HC412010GB Vartotojo vadovas [de] [en] [nl] , 76 paginas
B9931-5-M Guía de inicio rápido   Aeg-Electrolux B9931-5-M Pamata Lietošanas instrukcija, 4 paginas
FAV60850BIM Manual de usuario   Aeg-Electrolux FAV60850BIM Uživatelský manuál [hr] [tr] , 40 paginas
FAV64085VI Manual de usuario   Aeg-Electrolux FAV64085VI Benutzerhandbuch [ru] [ua] , 48 paginas
41056VH-MN Manual de usuario   Aeg-Electrolux 41056VH-MN Manual de utilizare [nl] , 32 paginas
E4000-4-LG Manual de usuario   Aeg-Electrolux E4000-4-LG Manuel utilisateur [en] , 44 paginas
FAV60860US Manual de usuario Aeg-Electrolux FAV60860U Brukermanual [fr] , 48 paginas
BE3003420M Manual de usuario   Aeg-Electrolux BE3003420M User Manual [en] , 28 paginas
E41.243-2M AW8 Manual de usuario   Aeg-Electrolux E41.243-2M AW8 Lietotāja rokasgrāmata, 8 paginas