Programming Worksheets
31
NOTE: Zones 9-32 are only available for wireless zones.
[002] Zone 9-16 Definitions
(Section 5.2 “Zone Programming”)
Default Default
00 I_______I_______I Zone 9 00 I_______I_______I Zone 13
00
I_______I_______I Zone 10 00 I_______I_______I Zone 14
00
I_______I_______I Zone 11 00 I_______I_______I Zone 15
00
I_______I_______I Zone 12 00 I_______I_______I Zone 16
[003] Zone 17-24 Definitions
(Section 5.2 “Zone Programming”)
Default Default
00
I_______I_______I Zone 17 00 I_______I_______I Zone 21
00
I_______I_______I Zone 18 00 I_______I_______I Zone 22
00
I_______I_______I Zone 19 00 I_______I_______I Zone 23
00
I_______I_______I Zone 20 00 I_______I_______I Zone 24
[004] Zone 25-32 Definitions
(Section 5.2 “Zone Programming”)
Default Default
00
I_______I_______I Zone 25 00 I_______I_______I Zone 29
00
I_______I_______I Zone 26 00 I_______I_______I Zone 30
00
I_______I_______I Zone 27 00 I_______I_______I Zone 31
00
I_______I_______I Zone28 00 I_______I_______I Zone 32
[005] System Times
Default Valid entries: [001-255]
030
I_______I_______I_______I Entry Delay 1 (in seconds)(Section 5.18 “Entry/Exit Delay Options”)
045 I_______I_______I_______I Entry Delay 2 (in seconds)(Section 5.18 “Entry/Exit Delay Options”)
120 I_______I_______I_______I Exit Delay (in seconds)(Section 5.18 “Entry/Exit Delay Options”)
004 I_______I_______I_______I Bell Cut-off (in minutes)(Section 5.13 “Bell”)
[006] Installer’s Code (Section 4.1 “Installer’s Programming”)
Default
5555 I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes”)
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code (Section 5.1 “Programming Security Codes”)
Default
AAAA I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.11 “PGM Output Options”)
Programmable Output Options
01 Burglary and Fire Bell Output 14 Ground Start Pulse
02 For future use 15 Remote Operation (DLS 2002 Support)
03 Sensor Reset 16 LINKS1000 Support (PGM1 only)
04 For future use 17 Away Armed Status
05 System Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 ([*][7][1])
07 Keypad Buzzer Follow Mode 20 Command Output #2 ([*][7][2])
08 Courtesy Pulse 21 For future use
09 System Trouble Output (with Trouble options) 22 For future use
10 System Event [Strobe (with Event options)] 23 For future use
11 System Tamper (all sources: zones, kpd, modules) 24 For future use
12 TLM and Alarm
13 Kissoff Output
NOTE: Output types [03] and [20] cannot be used together on the same system.
Default Default
19 I_______I_______I PGM 1 10 I_______I_______I PGM 2 Program PGM Option Attributes in sections [141] & [142].