Programming Sections: 5.3 Basic Programming PWS Sect 3
23
Option Definition On/Off Description
7 Telephone Line
Monitor
ON Telephone Line Monitor enabled. The TLM function will be active and the system will indicate a
Trouble #3 condition when using the [*][2] View Trouble Conditions Command.
OFF Telephone Line Monitor disabled. The TLM function will be shut off and telephone line troubles
will not be indicated by the system.
8 Telephone Line
Monitor Audible
Trouble
ON TLM Audible When Armed. When the system is disarmed, a telephone line monitor trouble will
generate a trouble indication as described above. If the system is armed, a telephone line monitor
trouble will generate an audible alarm on the bell or siren for the duration programmed for Bell Tim-
eout or until an access code is entered to disarm.
OFF TLM Trouble Only. A telephone line trouble will generate a trouble indication, the Trouble LED will
come ON, and the keypad sounder will beep until a key is pressed.
[016] - FOURTH SYSTEM OPTION CODES
Option Definition On/Off Description
1 AC Trouble Display ON AC Trouble Displayed. If AC power fails, the condition will be reported to the monitoring station
and will be indicated as a Trouble condition on the system Keypads.
OFF AC Trouble Not Displayed. If AC power fails, the condition will be reported, but the Trouble light
will not be indicated on the system keypads. If [*][2] is entered to view the system troubles, Trouble
#2 will still be displayed.
2 AC Trouble Flash ON Trouble Light Flashes if AC Fails. When AC power is lost from the system, the “Trouble” light will
flash in the base “Ready” and “Armed” mode within 30 seconds from after power is lost. When AC
restores, the “Trouble” light will stop flashing within 30 seconds. If enabled, this option will override
the AC display option.
OFF Trouble Light Does Not Flash on AC Fail.
3 Keypad Blanking ON Blank Keypad When Not Used. If no keys are pressed for 30 seconds, all keypad lights except
backlighting (if enabled) will be shut OFF until the next keypress, Entry delay, Audible Alarm or key-
pad buzzer condition.
NOTE: Keypad function keys will still operate when the keypad is blank, unless the function key is
programmed to require an access code.
OFF Keypad Always Active. The keypad lights will remain ON at all times.
4 Keypad Blanking
Restore
ON Access Code Required to remove Keypad Blanking. A valid access code must be entered before
a blanked Keypad can be used
OFF Access Code Not Required. Pressing any key on a blanked keypad will remove the blanking.
5 Keypad Backlight-
ing
ON Keypad Backlighting is Enabled. All keypads on the system will have backlighting on all of the
time.
OFF Keypad Backlighting is Disabled.
6 Power Save Mode ON Power Save Mode Enabled. If AC power fails, all keypad lights including backlighting will be shut
OFF. The keypad lights will come back ON after a keypress, Entry delay, Audible Alarm or keypad
buzzer condition (except Door Chime). The keypad lights will return to the off state after 30 seconds
of keypad inactivity.
OFF Power Save Mode Disabled.
7 Bypass Status Dis-
play
ON Bypass Status Displayed While Armed. The Bypass status light will be ON if there are zones
bypassed when the system is armed.
OFF Bypass Status Not Displayed While Armed. The Bypass light will be ON only while the system is
disarmed to indicate that there are bypassed zones on the system. When the system is armed, the
Bypass light will be OFF.
NOTE: The Bypass status LED will be ON if there are Stay/Away zones auto bypassed at the time of
arming regardless of whether or not this option is enabled. This option only enables and disables
manual bypass display.
8 Keypad Tampers ON Keypad Tampers are Enabled. All keypads containing Tamper switches will generate Tamper
Alarms and Restores (Sect 338).
OFF Keypad Tampers are Disabled.
NOTE: If this option is used, all keypads should be properly installed and secured (tamper restored)
before enabling the option.
[017] - FIFTH SYSTEM OPTION CODES
Option Definition On/Off Description
1 WLSKey Disarming ON WLS Keys Do Not Use Access Codes. The panel will accept the disarm keycode from an unidenti-
fied Wireless Key, allowing arming/disarming without a code.
NOTE:This option must be enabled when using a PC5132 v2.1 or earlier.
OFF
NOTE: WLS Keys Uses Access Codes. The panel will NOT accept the disarm keycode from an uni-
dentified Wireless Key. An Access code must be associated to a WKEY for proper operation.(Refer to
the PC5132 manual for information on programming wireless keys.)
NOTE: This option must be ON when using a PC5132 older than v3.00.
2 Auto-Arm Schedule
Programming
ON Auto-arm Schedule in [*][6]. The Auto-Arm Schedules (Sect [181] - [188]) are accessible via [*][6]
as well as Installer’s Programming.
OFF Auto-arm Schedule in Installer’s. Programming Only. The Auto-Arm Schedules (Sect [181] -
[188]) are only accessible via Installer’s Programming.
NOTE: This toggle controls access for all eight partitions