[390]-[393] LINKS Preambles
Downloading can be performed through the LINKS1000 cellular
communicator if the telephone line is disconnected. If using the
LINKS1000 with Call Back, you need to program the LINKS1000 Pre-
amble with the downloading telephone number in order for the
panel to call the computer correctly.
LINKS1000 Cellular Communicator
The LINKS1000 cellular communicator can be used three different
ways: as the sole communicator for the panel, as a back up for either
or both telephone numbers, or as a redundant back up to the land
line communicator (the panel will call both the land line and via the
LINKS1000). A LINKS1000 Preamble is programmable for each tele-
phone number in the event that the land line number is local but the
LINKS1000 is required to dial an exchange. When programming a
LINKS1000 Preamble, all unused digits must be programmed with a
hex decimal “F”.
Sole Communicator
The panel can be programmed to report only using the LINKS1000
cellular communicator when an event occurs. To program this select
only the LINKS1000 for the Communicator Call Direction Options
for the event. In addition the Call LINKS1000 as well as Land Line
option must also be enabled. When the selected event occurs the
panel will only attempt to call central station using the LINKS1000.
NOTE: If a LINKS1000-only event fails to communicate, the
LINKS1000 must successfully communicate a LINKS1000-only event
in order for the FTC trouble to clear.
Backup Communicator
The panel can be programmed to call using the LINKS1000 cellular
communicator if the panel is having difficulty communicating an
event using the land line. To program this select the telephone num-
ber and LINKS1000 options for the Communicator Call Direction
Options for the event. The LINKS1000 is Backup of Land Lines option
must also be selected.
When used as a backup communicator the panel will attempt to call
the central station in the following manner:
the panel will try to call using land lines - if unsuccessful the
panel will try to call using the LINKS1000
if unsuccessful the panel will try to call using the land lines
if unsuccessful the panel will try to call using the LINKS1000
This process will continue until the panel has successfully communi-
cated with the central station or the Maximum Dialing Attempts
has been reached.
[382] - THIRD COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
1 Contact I.D. Partial Closing
Identifier
ON Partial Closing Identifier = 5. Contact I.D. uses ‘5’ as the Identifier for the Partial Closing
event.
OFF Partial Closing Identifier = 4. Contact I.D. uses ‘4’ as the Identifier for the Partial Closing
event. This option is defaulted OFF.
2 Walk Test Communication ON Zone Alarms Communicate during Walk Test Enabled. Zone alarms that occur during Walk
Test will communicate if programmed to do so.
OFF Zone Alarms Communicate during Walk Test Disabled. Zone alarms that occur during Walk
Test will not communicate even if programmed.This option is defaulted OFF.
3 Communications Cancelled
Message
ON Communications Cancelled Message Enabled. The “Communications Cancelled”
(LCD5500Z) or “CC” (LCD5501Z) message will be displayed if alarms are acknowledged during
the Transmission Delay time. This message will be displayed for 5 seconds on all keypads on the
partition. The acknowledgment can be from an access code, disarm function key, or a keyswitch
zone. Caution: This option must NOT be turned OFF for SIA-FAR installations.
OFF Communications Cancelled Message Disabled. The “Communications Cancelled” message
will not be displayed. This option is defaulted OFF.
4 Call Waiting Cancel ON Call Waiting Cancel Enabled. The Call Waiting dialing string programmed in Section [304] will
be dialed before the first attempt of each phone number. All subsequent dialing attempts to the
same phone number will not use the Call Waiting Cancel dialing string.
OFF Call Waiting Cancel Disabled. The Call Waiting dialing string will not be dialed. This option is
defaulted OFF. Note: A call waiting cancel on a non-call waiting line will prevent successful
connection to the central station.
6 AC Failure Transmission
Delay
ON AC Failure Transmission Delay. Delay is in Hours.
OFF AC Failure Transmission Delay. Delay is in Minutes.
7-8 ON Reserved For Future Use
WWW.DIYALARMFORUM.COM