36
Redundant Communicator
The panel can be programmed to call using the land line and the
LINKS1000 cellular communicator when an event occurs. To program
this select both the telephone number and the LINKS1000 options
for the Communicator Call Direction Options for the event. In
addition the Call LINKS1000 as well as Land Line option must be
selected. The panel will call the LINKS1000 and then call the land line
when reporting the selected event.
LINKS1000 Special Preamble
In some areas of North America, dialing #DAT or *DATA reduces the
cellular billing increment. The LINKS1000 Special Preamble (sec-
tion [393]), allows the use of [*] and [#] characters for the program-
ming of #DAT and *DATA. The LINKS1000 Special Preamble is sent
BEFORE the Preamble programmed in Sections [390] to [392]. Exam-
ple: [Special Preamble][Regular Preamble][Telephone Number]
NOTE: If this Special Preamble is programmed, it will be inserted
before the Regular Preamble of ALL telephone numbers. Hex digits D
and E are not supported for Preamble programming. If Busy Tone
Detection is enabled, the LINKS1000 must be tested to ensure full
operation.
Refer to the LINKS1000 Installation Manual for more information
and connection diagrams.
(Downloading Telephone Number) . . . . . . . . . . . . . . . Section [490]
Communicator Call Direction Options . . . . . Section [351] to [376]
Call LINKS1000 as well as Land Line . . . . . Section [380], Option [7]
Maximum Dialing Attempts . . . . . . . . . . . . . . . . . . . Section [165][
This 4-digit number can be used with long distance telephone num-
bers that are dialed through the LINKS Module. These codes are used
for programming area codes in cases where a land line telephone
number may be a local call, while the cellular telephone number
dialed by the LINKS module is a long distance call.
[393] - LINKS Special Function Preamble
This special preamble is inserted before all other preambles. It is used
for dialing such cellular numbers as #DAT and *DATA for reduced
billing increments.
5.7 Downloading Options PWS Sect 7
Downloading
Downloading allows programming of the entire control panel via a
computer, modem and telephone line. All functions and features,
changes and status, such as trouble conditions and open zones can
be viewed or programmed by downloading.
NOTE: When power is applied to the panel, a 6 hour downloading
window can be enabled. This will allow you to perform downloading
without having to do any keypad programming.
NOTE: When an event occurs that the system is programmed to
communicate to the central station, the panel will disconnect from
the downloading computer and report the event. This will happen
for all events except test transmissions.
If the Answering Machine/Double Call option is enabled (or dur-
ing the first 6 hours after power up) the panel will answer incoming
calls for downloading provided the following conditions occur:
1. The panel hears one or two rings then misses a ring.
2. At this point the panel will start a timer.
3. If the panel hears another ring before the Answering Machine
Double Call Timer expires it will answer on the first ring of the
second call.
The panel will immediately go on line and begin the download pro-
cess unless the Call Back option is enabled. If enabled, the panel and
computer will both hang up. The panel will then call the Download
Computer Telephone Number and wait for the computer to
answer. Once the computer answers downloading will begin.
If the User Enabled DLS Window option is ON, the user can acti-
vate the downloading feature by entering [*][6][Master Code][5].
Six hours after power up, the panel will not answer incoming calls
unless the Answering Machine/Double Call option is enabled, or
the Number of Rings is programmed to be more than [0].
If the User Initiated Call-Up option is enabled, the user can have
the panel initiate a call to the downloading computer by pressing
[*][6][Master Code][6].
The Download Access Code and Panel Identifier Code are for
security and proper identification. Both the panel and the computer
file should have the same information programmed before attempt-
ing to download.
The time to complete a successful download can be significantly
reduced with the use of the PC-Link. This adaptor makes it possible
to perform on-site downloading. To Initiate Local Downloading
via the PC-Link, enter [
] [8] [Installer’s Code] [499] [Installer’s
Code] [499]. All keypads will be busy for the duration of the PC-Link
connection. The status LEDs will display the current system status on
the keypad where the PC-Link was initiated. For more information on
connecting the PC-Link, refer to your “PC-Link Download Kit Instruc-
tion Sheet”.
Downloading can also be performed through the LINKS1000 cellular
communicator if the telephone line is disconnected. If using the
LINKS1000 with Call Back, you need to program the LINKS1000
Preamble with the downloading telephone number in order for the
panel to call the computer correctly.
NOTE: When uploading labels from LCD keypads, the DLS software
will receive the labels only from the LCD keypad assigned to slot 8. In
addition, version 1.0 and version 2.0 LCD keypads are not compati-
ble on the same system. For more information refer to the Download
Manual included with the computer software.
NOTE: The most recent version of the LCD5500 keypad on the sys-
tem should be assigned to slot 8.
Answering Machine Double Call Timer . . . . . . . . . . . Section [405]
Download Computer Telephone Number . . . . . . . . . Section [402]
Download Access Code. . . . . . . . . . . . . . . . . . . . . . . Section [403]
Panel Identifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [404]
LINKS1000 Preamble (Downloading) . . . . . . . . . . . . . Section [490]
WWW.DIYALARMFORUM.COM
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 52 53

Comentarios a estos manuales

Sin comentarios