Programming Sections: 5.11 Special Installer Instructions PWS Sect 11
41
[991][Installer Code] - Installer Lockout Disable
This disables the Installer Lockout feature described above.
To disable Installer Lockout perform the following:
1. Enter Installer Programming.
2. To disable Installer Lockout, enter section [991].
3. Enter the Installer Code.
4. Enter section [991] again.
[993]-[999] Factory Defaults
On occasion it may be necessary to default the main control panel or
one of the modules that can be connected. There are several differ-
ent defaults available including defaulting the main control panel,
Escort5580 module, PC5132 Wireless Expander Module, PC5400
Printer module and LINKS2X50 module.
NOTE: Defaulting the main panel does not default the keypads.
Refer to the Programming Worksheets Appendices A and B for
instructions for defaulting LCD5500Z and LCD5501Z keypads.
PC55XXZ LED keypads must be manually reprogrammed in program-
ming section [000].
Factory Default Main Panel (Hardware)
1. Remove AC and battery from the panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire short the Zone 1 terminal to the PGM1 ter-
minal.
4. Apply AC power to the main panel.
5. When Zone Light 1 is lit on the keypad the default is complete.
6. Remove AC power from the control
7. Reconnect all original wiring and power up the control.
NOTE: AC power must be used to power the panel. The panel will
not default if the battery is used.
Factory Default Main Panel (Software) and other
Modules
1. Enter Installer Programming.
2. Enter the appropriate programming section [99X].
3. Enter the Installer Code.
4. Enter the appropriate programming section [99X] again.
The panel will take a few seconds to reset. When the keypad is oper-
ational, the default is complete.
[993][Installer Code] - Restore Alternate Comm. Fac-
tory Default Programming
When this section is successfully entered, all programming in the
Alternate Communicator (LINKS2150, LINKS2450, LINKS3000, or
PC5400 DVACS Module) will be returned to the factory defaults.
[995][Installer Code] - Restore ESCORT 5580 Factory
Default Programming
When this section is successfully entered, all programming in the
ESCORT 5580 Module will be returned to the factory defaults.
[996][Installer Code] - Restore PC5132 Wireless Factory
Default Programming
When this section is successfully entered, all programming in the
PC5132 Wireless Expansion Module will be returned to the factory
defaults.
[997][Installer Code] - Restore PC5400 Factory Default
Programming
When this section is successfully entered, all programming in the
PC5400 Serial Module will be returned to the factory defaults.
[998][Installer Code] - Restore PC59XX Factory Default
Programming
When this section is successfully entered, all programming in the
PC59XX Audio Matrix Module will be returned to the factory defaults.
[999][Installer Code] - Restore Factory Default Pro-
gramming
When this section is successfully entered, all programming in the
PC5020 will be returned to the factory defaults. The programming
for the ESCORT, PC5132, PC5400 and PC59XX modules will not be
defaulted. When this command is executed, the Module Supervision
Field will be reset.