37
[402] - Downloading Computer’s Telephone Number
This telephone number is 32 digits in length.
[403] - Downloading Access Code
This 4-digit Hexadecimal code allows the panel to confirm that it is
communicating with a valid downloading computer.
[404] - Panel Identification Code
This 4-digit Hexadecimal code allows the downloading computer to
confirm the identity of the control panel.
[405] - Double-Call Timer
This timer sets the amount of time that can be taken between calls
when using Double Call to contact the panel.
Valid entries are 001 to 255 (seconds).
[406] - Number of Rings to Answer On
The value in this section determines how many rings that the panel
will automatically pick up on in order to establish a DLS connection.
Default value is 000 rings. Valid entries are [000]-[020].
NOTE: If Section [401] Option 1 and Section [406] are enabled, either
one will work depending on how the installer calls the premises.
[490] - LINKS DLS Phone Number Preamble
Refer to Section [390].
[499] - Initiate PC-LINK Communications
The installer may initiate a PC-LINK DLS session between a computer
and panel by entering this section in the following manner:
[499] - [Installer’s Code] [499].
The installer should already have the PC-LINK Cable properly con-
nected between the panel’s header and the downloading computer
as well as have the DLS file waiting for the panel to connect before
entering this command.
5.8 Programmable Output Programming
PWS Sect 8
[501]-[515] - Programmable Output Attributes
PGM output attributes and output type must be programmed for
each PGM output. PGM output options [09] “System Trouble” and
[10] “Latched System Event” have a unique set of attributes listed
below the description of each output type.
PGM attributes return to their default settings when PGM output
options are changed . See the programming worksheets for a list of
the default settings for each PGM output type.
CAUTION: Select the normal and active states of each PGM output
to ensure that undesirable output states do not occur after a loss and
restore of AC power.
If you program more than one PGM output as the same output type
(e.g. If PGM 1 and PGM 2 are both programmed as [19] Command
Output 1), the settings for output attributes [1], [2] and [5] must be
the same. This does not apply to outputs programmed as types [09]
and [10].
NOTE: Attribute [3] must be ON for PGM output option [16].
Assigning Partitions to Programmable Outputs
By default, all programmable outputs are assigned to partition 1. For
programmable outputs to work on other partitions, enable or disable
the appropriate partitions in the Partition Assignment programming
sections.
PGM Output Partition Assignment . . . . . . . . .Sections [551] - [564]
PGM Output timer . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [170]
[401] - First Downloading Option Codes
Option Downloading Code On/Off Description
1 Downloading Answer ON Downloading Answer Enabled. The system will answer calls for downloading if a successful
Double call routine is detected. Have the downloading computer call the system and let the tele-
phone line ring once or twice. After 1 or 2 rings, hang up. If called back within the programmed
Double Call Time (000-255 seconds), the panel will answer on the first ring.
OFF Downloading Answer Disabled. The system will not answer incoming calls using the Double
Call routine unless the User enables the DLS window. This option can be enabled by turning
Option 2 ON.
2 DLS Window ON User Can Enable DLS Window. The user can use the [*][6][Master Code][5] Command to
enable a 6 hour window in which the panel will answer calls for downloading if a successful
Double Call routine is detected. If this option is enabled, the window is open upon power up.
The window is on for the full 6 hours if enabled.
OFF User Can Not Enable DLS Window. The user can not enable a window for DLS calls.
NOTE:Note: Options 1 and 2 are not related. One does not need to be enabled for the other to
perform its function.
3 Call-Back ON Call-Back Enabled. When the system answers the downloading computer’s call, both the com-
puter and the panel will hang up. The panel will then call the Downloading Telephone Number
and connect with the computer at that number. If more than one downloading computer is to
be used, this function should be disabled.
OFF Call-Back Disabled. The downloading computer will have immediate access to the panel once
it is identified as a valid system.
4 User Call-Up ON User Call-Up Enabled. When this feature is enabled, the user may initiate a single call of the
Downloading Telephone by entering [*][6][Master Code][6].
OFF User Call-Up Disabled. An error tone will be generated when [*][6][Master Code][6] is
entered.
5-8 For Future Use
[501]-[515] PROGRAMMABLE OUTPUT ATTRIBUTES
PGM Output Types [01], [03], [04], [05]-[08], and [17]-[18]
1 Not Used
NOTE: This option must be off to ensure proper PGM operation.
2 Not Used
NOTE: This option must be off to ensure proper PGM operation.
3 Output Level ON The output will activate (switch to Ground) when the event occurs.
OFF The output will de-activate (switch to open) when the event occurs.
PGM Output Types [03], and [19]-[22].ON
4 Output Options ON Output Pulsed. The output will activate for the duration programmed in for the PGM Output
Timer in Section [164]. This default period is five seconds.
OFF Output On/Off. The output will toggle between on and off when the corresponding [*][7]
command is entered.
WWW.DIYALARMFORUM.COM
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 52 53

Comentarios a estos manuales

Sin comentarios

AEG Electrolux HM604060MB manuales

Manuales del propietario y guías del usuario para No AEG Electrolux HM604060MB.
Ofrecemos 6 manuales en pdf AEG Electrolux HM604060MB para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para No AEG Electrolux

Modelos Tipo de documento
FAV35080IM Manual de usuario   Aeg-Electrolux FAV35080IM Benutzerhandbuch, 44 paginas
EE4003011M Manual de usuario   Aeg-Electrolux EE4003011M Handleiding [en] , 28 paginas
FM2500DD-A Manual de usuario   Aeg-Electrolux FM2500DD-A Benutzerhandbuch [de] [en] [fr] , 20 paginas
HK634150XB Manual de usuario   Aeg-Electrolux HK634150XB Uživatelský manuál, 16 paginas
B9878-5-M Manual de usuario   Aeg-Electrolux B9878-5-M Food Index [it] , 24 paginas
BE3003000M Manual de usuario   Aeg-Electrolux BE3003000M Manuel utilisateur, 28 paginas
BP9314001M Libro de recetas   Aeg-Electrolux BP9314001M Recipe Book, 56 paginas
47745IQ-WN Manual de usuario   Aeg-Electrolux 47745IQ-WN Ohjekirja, 76 paginas
30006FFW GR R07 Manual de usuario Aeg-Electrolux 30006FFW GR R07 Εγχειρίδιο χρήστη, 52 paginas
E3050-6-M Manual de usuario   Aeg-Electrolux E3050-6-M User Manual, 24 paginas
41056VH-MN Manual de usuario   Aeg-Electrolux 41056VH-MN Používateľská príručka, 32 paginas
HC412010GB Manual de usuario     Aeg-Electrolux HC412010GB Vartotojo vadovas [de] [en] [nl] , 76 paginas
B9931-5-M Guía de inicio rápido   Aeg-Electrolux B9931-5-M Pamata Lietošanas instrukcija, 4 paginas
FAV60850BIM Manual de usuario   Aeg-Electrolux FAV60850BIM Uživatelský manuál [hr] [tr] , 40 paginas
FAV64085VI Manual de usuario   Aeg-Electrolux FAV64085VI Benutzerhandbuch [ru] [ua] , 48 paginas
41056VH-MN Manual de usuario   Aeg-Electrolux 41056VH-MN Manual de utilizare [nl] , 32 paginas
E4000-4-LG Manual de usuario   Aeg-Electrolux E4000-4-LG Manuel utilisateur [en] , 44 paginas
FAV60860US Manual de usuario Aeg-Electrolux FAV60860U Brukermanual [fr] , 48 paginas
BE3003420M Manual de usuario   Aeg-Electrolux BE3003420M User Manual [en] , 28 paginas
E41.243-2M AW8 Manual de usuario   Aeg-Electrolux E41.243-2M AW8 Lietotāja rokasgrāmata, 8 paginas