The switched auxiliary output terminal on the main panel is a 12 volt power supply. It can be activated and
deactivated by any one of 56 programmable output options. Normally the output energizes when it is
activated. The output will de-energize when it is activated if any “INV” options are selected. The switched
auxiliary output, for some options can also be programmed to activate for only selected areas.
Program the output type from the list of 56 output options (see “Programmable Output Options”).
Depending on which output option you select, you may also need to program the area(s) the output will
be active on, which zone the output will follow, which date schedule the output will follow, and/or a
pulse timer for the output.
Typically, this output is used for providing power to latching type devices that require a power
interruption in order to reset.
For example:
The SW AUX output has been programmed for Sensor Reset and enabled on area 1 and area 2. User 005
has been assigned to area 1. When user 005 select answers Yes to “Do you want to reset detectors?”, the
output will deactivate for the amount time programmed in “PGM Pulse Time”.
NOTE: Refer to “Programmable Output Options” for a list of available programmable output types.
SW AUX OUTPUTSW AUX OUTPUT
SW AUX OUTPUTSW AUX OUTPUT
SW AUX OUTPUT
(04)(04)
(04)(04)
(04)
Switched Auxiliary Output
The bell output on the main control board can be programmed to activate for any one of the 56
programmable output options, on any number of areas. The BELL+ terminal is always 13.8 VDC. The BELL-
terminal is normally 12.6 VDC. This voltage difference is required for bell circuit supervision. When the bell
output is activated, the panel will switch BELL- to ground.
The Bell output is supervised. If no alarm warning devices are in use, connect a 1000 ohm resistor (brown,
black, red, gold) across BELL+ and BELL– to prevent the panel from displaying a trouble condition.
Program the output type from the list of 56 output options (see “Programmable Output Options”).
Depending on which output option you select, you may also need to program the area(s) the output will
be active on, the zone the output will follow, the date schedule the output will follow, and/or a pulse
timer for the output.
NOTE: Refer to “Programmable Output Options” for a list the available programmable output types.