Add/Edit Area. Only area 1 is enabled by default. To enable more areas, select the Add/Edit area section,
then select the area. The area is now enabled.
The PC6010 can be divided into 32 areas. Select an area to program in this section.
Each area has its own 6 digit customer account number that will be transmitted to the central station
when a reporting code is sent. The central station uses the code to identify the customer.
Area Toggles
You can enable or disable any of the following options for each area.
Autoarm enabled?
YES = Auto Arm control enabled.
NO = Auto Arm control disabled. If disabled, areas will not be able to autoarm.
Autoarm squawk enabled?
YES = The bell output will activate for one second every ten seconds during the auto-arm pre-alert.
NO = The bell output will not activate during auto-arm pre-alert.
Bell squawk enabled?
YES = The bell output will activate once briefly when the area is armed, twice when disarmed. All
outputs, when programmed for “Fire and Burg”, “Inv Fire/Burg”, “Burg Only” or “Inv Burg Only”,
will squawk for the assigned area(s).
NO = Bell Squawk disabled.
Bell squawk exit delay?
YES = Bell squawks once every second on exit delay. During the last 10 seconds, bell will squawk twice
every second.
NO = Silent bell on exit delay.
Audible exit fault?
YES = Zone delay will sound the siren for entry delay if zone is still violated at the end of exit delay.
NO = Siren will not be on for entry delay if zone is still violated at the end of exit delay.
Bell squawk entry delay?
YES = Bell squawks once every second on entry delay. During the last 10 seconds, bell will squawk twice
every second.
NO = Bell is silent during entry delay.
Exit delay termination?
YES = During the exit delay exiting through a standard delay, or a force arm delay zone will set the
remainder of the exit delay to 5 seconds once the zone has been restored.
NO = Exit delay will not terminate when a standard delay, or a force arm delay zone is tripped.
NOTE: Do not use Exit Delay Termination with Global Standard Delay Zones.
ADD/EDIT AREAADD/EDIT AREA
ADD/EDIT AREAADD/EDIT AREA
ADD/EDIT AREA
(0)(0)
(0)(0)
(0)
“AREA X”“AREA X”
“AREA X”“AREA X”
“AREA X”
(01) (01)
(01) (01)
(01)
(32) (32)
(32) (32)
(32)
AREA ID CODEAREA ID CODE
AREA ID CODEAREA ID CODE
AREA ID CODE
(0)(0)
(0)(0)
(0)
Area Section
AREA TOGGLESAREA TOGGLES
AREA TOGGLESAREA TOGGLES
AREA TOGGLES
(1)(1)
(1)(1)
(1)
AUTOARM ENABAUTOARM ENAB
AUTOARM ENABAUTOARM ENAB
AUTOARM ENAB
YY
YY
Y
AUTOARM SQUAWKAUTOARM SQUAWK
AUTOARM SQUAWKAUTOARM SQUAWK
AUTOARM SQUAWK
YY
YY
Y
BELL SQUAWK ONBELL SQUAWK ON
BELL SQUAWK ONBELL SQUAWK ON
BELL SQUAWK ON
NN
NN
N
SQUAWK EX.DELSQUAWK EX.DEL
SQUAWK EX.DELSQUAWK EX.DEL
SQUAWK EX.DEL
NN
NN
N
AUD.EXIT FAULTAUD.EXIT FAULT
AUD.EXIT FAULTAUD.EXIT FAULT
AUD.EXIT FAULT
NN
NN
N
SQUAWK EN.DELSQUAWK EN.DEL
SQUAWK EN.DELSQUAWK EN.DEL
SQUAWK EN.DEL
NN
NN
N
EXIT DEL.TERM.EXIT DEL.TERM.
EXIT DEL.TERM.EXIT DEL.TERM.
EXIT DEL.TERM.
NN
NN
N
Vista de pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 51 52

Comentarios a estos manuales

Sin comentarios