SYSTEM AREASYSTEM AREA
SYSTEM AREASYSTEM AREA
SYSTEM AREA
PGM OUTPUTSPGM OUTPUTS
PGM OUTPUTSPGM OUTPUTS
PGM OUTPUTS
This output will follow a selected zone. Any one of the 256 zones can be selected. If the zone is opened,
the output will activate. When the zone is closed the output will deactivate.
See “Follows + Alarms” for enabling the output to be a zone follower and zone alarm annunciator.
This output will be turned on for the selected area(s) when a duress type code is used to perform any
function. It will follow the duress output timer.
This output will activate when a programmed area(s) keypad buzzer activates for Entry Delays, Auto Arm
Pre-alert, 24 Hour Buzzer, Tamper and Door Strike.
This option can be remotely activated by area with DLS-3, and remains active until deactivated by the DLS-
3 package.
This option will follow the exit delay timer of the area(s) it is assigned to.
This option will follow the entry delay timer of the area(s) it is assigned to.
This PGM output type may be programmed to follow any one of 99 date schedules. The schedule which the
output is programmed to follow may be activated at any time, and may remain on for up to 24 hours. See “Date
Schedule” for programming details.
This output type will activate when a Hold Up zone has been tripped for the selected area. The output will latch
on when activated. The output will remain active until a valid access code is entered. If the area is already
disarmed the output will remain active until an access code is entered.
This output will activate only when the selected area(s) are fully armed and will remain active until the area is disarmed.
The term “Fully Armed” refers to the area being armed with no zones bypassed, disabled or force armed and all
interior zones armed. The output will deactivate if one or more zones in the area(s) are in alarm. If the output is
programmed to follow more than one area, then the output will not activate until all assigned areas are fully armed.
There are four different “Trouble Groups” that this output type may follow. Each output that is programmed
as Trouble Group may only follow one group at a time. The troubles are divided as follows:
ZONE FOLLOWZONE FOLLOW
ZONE FOLLOWZONE FOLLOW
ZONE FOLLOW
(18)(18)
(18)(18)
(18)
DURESS OUTPUTDURESS OUTPUT
DURESS OUTPUTDURESS OUTPUT
DURESS OUTPUT
(19)(19)
(19)(19)
(19)
BUZZER FOLLOWBUZZER FOLLOW
BUZZER FOLLOWBUZZER FOLLOW
BUZZER FOLLOW
(20)(20)
(20)(20)
(20)
REMOTE OPERATIONREMOTE OPERATION
REMOTE OPERATIONREMOTE OPERATION
REMOTE OPERATION
(21)(21)
(21)(21)
(21)
EXIT FOLLOWEXIT FOLLOW
EXIT FOLLOWEXIT FOLLOW
EXIT FOLLOW
(22)(22)
(22)(22)
(22)
ENTRY FOLLOWENTRY FOLLOW
ENTRY FOLLOWENTRY FOLLOW
ENTRY FOLLOW
(23)(23)
(23)(23)
(23)
DATE SCHEDULEDATE SCHEDULE
DATE SCHEDULEDATE SCHEDULE
DATE SCHEDULE
(24)(24)
(24)(24)
(24)
HOLD UPHOLD UP
HOLD UPHOLD UP
HOLD UP
(25)(25)
(25)(25)
(25)
SETSET
SETSET
SET
(26)(26)
(26)(26)
(26)
TROUBLE GROUPTROUBLE GROUP
TROUBLE GROUPTROUBLE GROUP
TROUBLE GROUP
(27)(27)
(27)(27)
(27)
Group #1 Group #2 Group #3 Group #4
6010 Battery Trouble
6010 AC Trouble
6010 AUX Supply Trouble
6010 TLM Trouble
6010 FTC Trouble
6010 Bell Circuit Trouble
6010 Fire Trouble
Module Communication Fault
6204 Battery Trouble
6204 AC Trouble
6204 AUX Trouble
6820 Battery Trouble
6820 AC Trouble
6820 AUX Trouble
6820 Reader Power Trouble
6820 Lock Device Failure
6442 Battery Trouble
6442 AC Trouble
6442 AUX Trouble
6443 Battery Trouble
6443 AC Trouble
6443 AUX Trouble
PC6442 Aps Comm. Fault
PC6443 ODS Comm. Fault
AC Trouble
6204 AC Trouble
6820 AC Trouble
6442 AC Trouble
6443 AC Trouble
6010 Battery Trouble
6010 AUX Supply Trouble
6010 TLM Trouble
6010 FTC Trouble
6010 Bell Circuit Trouble
6010 Fire Trouble
Module Comm. Fault
6204 Battery Trouble
6204 AUX Trouble
6820 Battery Trouble
6820 AUX Trouble
6820 Reader Power Trouble
6820 Lock Device Failure
6442 Battery Trouble
6442 AUX Trouble
6443 Battery Trouble
6443 AUX Trouble
Zone Tamper
Zone Fault
Seismic Detector Test Fault
Battery Trouble