A 24 Hour Bell zone is active at all times, and will create an alarm whether the area is armed or disarmed.
This zone will not go into alarm if the zone is bypassed.
This zone operates like the 24 hour bell option except the bell output terminals are activated when the
area is armed, and the keypad buzzer will be activated when the area is disarmed.
Operates the same as the 24 hour bell, except this zone will only activate the keypad buzzer.
A fire zone is a 24 Hour zone that is specially used for fire detection circuits. On alarm, the bell output will
pulse the bells to indicate that the fire loop has been activated. The communicator will immediately
transmit the alarm to the central station if a reporting code is programmed.
If the fire zone is open circuit, the keypads will beep every 10 seconds and a fire zone trouble will be
displayed on the LCD. If programmed the communicator will transmit the trouble to the central station.
NOTE: Do NOT program fire zones as silent. Do NOT use Double EOL resistors with this zone type.
Automatically Verifying Fire Zone.
This zone works the same way as the Standard Fire Zone, with the exception that it will reset the smoke
detectors and wait for them to go into alarm again before sounding the bells and transmitting the alarm
to the central station. If the smoke detectors do not go into alarm again, the system assumes there is a
false alarm and will not initiate a fire alarm.
To activate an automatically verifying fire zone, the smoke detectors must be powered by the SW AUX
power supply on the main panel, or controlled by a relay on a PC6204 module. Otherwise the PC6010
has no control over the power to the sensors.
When an automatically verifying fire zone is shorted, the PC6010 performs a sensor reset, which removes
the power from the smoke detectors for 20 seconds. All SW AUX, BELL or PGM outputs programmed for
“Sensor Reset” will be activated. The outputs will be deactivated for 20 seconds, regardless of the time
programmed in the “PGM Pulse Times” section. After 20 seconds, the system will restore power to the
sensors, and all fire zone troubles will be bypassed for 10 seconds to allow the detectors to settle.
If the smoke detectors initiate another alarm within 60 seconds after the power is restored, a fire alarm
will immediately sound and the central station will be notified.
If the smoke detector is not reset during the sensor reset, the zone will not be restored. Because the zone
is not restored, a fire alarm will be initiated immediately.
See “Programmable Outputs” for programming outputs for Sensor Reset. See the PC6204 Installation
Instructions for information on powering smoke detectors. See the PC6010 Wiring Diagram in the System
Manual for information on using the SW AUX on the main panel to power the smoke detectors.
NOTE: Do NOT program fire zones as silent. Do NOT use Double EOL resistors with this zone type.
A momentary closure of this zone will alternately arm and disarm the area. This zone can be used as a
keyswitch to arm and disarm the system.
NOTE: Do not assign zones of this type to more than one area. Do not make this zone type bypassable.
When the zone is closed the area will disarm. When the zone is opened the area will be armed.
NOTE: Do not make this zone type bypassable.
This zone type is a 24 hour silent zone. It will activate its own “Hold Up” output when tripped. This zone
type will not activate Burglary outputs.
This zone type will generate an instant alarm once the area(s) it is assigned to is armed and the exit delay
has expired.
A 24 Hour Auxiliary zone is armed at all times, and will create an alarm when violated if the area is armed
or disarmed. An auxiliary alarm reporting code will be transmitted (if programmed) when the zone goes
into alarm.
24 HR BELL/BUZZ24 HR BELL/BUZZ
24 HR BELL/BUZZ24 HR BELL/BUZZ
24 HR BELL/BUZZ
(06)(06)
(06)(06)
(06)
24 HR BUZZER24 HR BUZZER
24 HR BUZZER24 HR BUZZER
24 HR BUZZER
(07)(07)
(07)(07)
(07)
STANDARD FIRESTANDARD FIRE
STANDARD FIRESTANDARD FIRE
STANDARD FIRE
(08)(08)
(08)(08)
(08)
AUTO VER FIREAUTO VER FIRE
AUTO VER FIREAUTO VER FIRE
AUTO VER FIRE
(09)(09)
(09)(09)
(09)
MOMENTARY ARMMOMENTARY ARM
MOMENTARY ARMMOMENTARY ARM
MOMENTARY ARM
(10)(10)
(10)(10)
(10)
MAINTAINED ARMMAINTAINED ARM
MAINTAINED ARMMAINTAINED ARM
MAINTAINED ARM
(11)(11)
(11)(11)
(11)
HOLD UPHOLD UP
HOLD UPHOLD UP
HOLD UP
(12)(12)
(12)(12)
(12)
AUXILIARYAUXILIARY
AUXILIARYAUXILIARY
AUXILIARY
(13)(13)
(13)(13)
(13)
24HR AUXILIARY24HR AUXILIARY
24HR AUXILIARY24HR AUXILIARY
24HR AUXILIARY
(14)(14)
(14)(14)
(14)
24 HR BELL24 HR BELL
24 HR BELL24 HR BELL
24 HR BELL
(05)(05)
(05)(05)
(05)